Siemens 5SL6401-7BB — 4-Pole MCB (DIN Rail)

Siemens 5SL6401-7BB SENTRON MCB, 1A C-Curve 4P 6kA

MPN5SL6401-7BB

Siemens SENTRON 5SL6 series, 5SL6401-7BB miniature circuit breaker, 4-pole, 1 A rated, C tripping characteristic, 6 kA breaking capacity per EN 60898 / IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6401-7BB — Identification
ParameterValue
Type / order code5SL6
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6401-7BB — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC1 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)60 V
Voltage typeAC
Rated frequency50 Hz
5SL6401-7BB — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-26 kA
Overvoltage category3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SL6401-7BB — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
SealableYes
5SL6401-7BB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SL6401-7BB — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Integrator note: 5SL6401-7BB

The Siemens 5SL6401-7BB is a 4-pole SENTRON miniature circuit breaker (MCB) from the 5SL6 design family, rated 1 A with a C tripping characteristic. The C-curve means it trips at 5–10× rated current — standard for general-purpose loads like lighting, small transformers, and control circuits where moderate inrush is expected. Breaking capacity is 6 kA per both EN 60898 and IEC 60947-2, so it's suitable for residential and light commercial distribution boards where the prospective fault current stays under that threshold. Rated voltage is 400 V AC phase-to-phase (440 V max), with a maximum DC rating of 60 V. The 4-pole (4P) configuration switches all three phases plus neutral — note that neutral conductor switching is not provided, meaning the neutral pole is a switched pole but the product feature for dedicated neutral switching is absent; treat it as a 4-pole breaker where the neutral pole tracks the phases. Mounting position is any, and the 72 mm width (4 width units) snaps onto standard DIN rail. Conductor range accepts solid or stranded from 0.75 to 25 mm², with a recommended tightening torque of 2.5–3 N·m. Ambient temperature range is -25 to +45 °C, with periodic tolerance to +55 °C at up to 95% humidity. The housing is halogen-free and silicon-free — relevant for environments sensitive to outgassing, such as clean manufacturing or enclosed panels near sensitive electronics.

Panel integration & compliance

Snaps onto standard 35 mm DIN rail. The 76 mm depth (70 mm installation depth) leaves room for wiring behind the panel door. IP20 protection with connected conductors — it's touch-safe when wired but not rated for washdown or outdoor exposure. Overvoltage category III per the evidence, so it's designed for fixed installation downstream of the main distribution board. The sealable feature allows the installer to lock the toggle in the off position with a padlock, meeting lockout/tagout requirements. Compliance documentation typically includes RoHS, REACH, and the relevant IEC/EN standards; the part is designed per EN 60898 and IEC 60947-2 as stated in the breaking capacity ratings.

MPN