Skip to main content
Siemens 5SL6402-7 — Miniature Circuit Breakers (MCB)

Siemens 5SL6402-7 SENTRON MCB, 4P C 2A 6kA 400V

MPN5SL6402-7
Active

Siemens SENTRON 5SL6402-7, miniature circuit breaker, 4-pole, C-curve, 2 A rated, 6 kA breaking capacity per IEC 60898 / IEC 60947-2, 400 V AC, 4 modular width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6402-7 — Ratings
ParameterValue
Overvoltage categoryIII
5SL6402-7 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The Siemens SENTRON 5SL6402-7 is a 4-pole miniature circuit breaker with C-curve trip characteristic, rated 2 A at 30 °C and 400 V AC, with a 6 kA breaking capacity certified to both EN 60898 and IEC 60947-2. At 40 °C the continuous rating derates to 1.9 A, and at 55 °C to 1.75 A — factor that into panel thermal calculations if the breaker shares a crowded enclosure. For DC applications the maximum rated voltage is 72 V — verify polarity and arc extinction if using in a DC subpanel.

Depth behind the panel is 70 mm; overall depth 76 mm. The 72 mm width (4 MW) matches the standard 18 mm/module grid — no special end plates or adapters needed for a typical distribution board. Touch protection is built in (fingertip-safe terminals when wired). Sealable with a lead or tag for tamper-evident installations.

Mechanical endurance is 10,000 switching cycles typical, which is adequate for branch-circuit protection where the breaker is operated infrequently.

The neutral conductor is not switched on this 4-pole breaker (3 poles + solid neutral). Confirm the system grounding scheme before specifying — if a switched neutral is required, a different variant in the 5SL series would be needed.

Frequently asked questions

Where can I buy 5SL6402-7 and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 5SL6402-7 drop into a panel specified around 5SL4120-7CC without rewiring?

Both are 4-pole MCBs in the SENTRON family with the same 4 MW (72 mm) width and DIN-rail mount, so the physical fit is identical. The key difference is the rating: 5SL6402-7 is a 2 A C-curve, while 5SL4120-7CC is a different rating/curve — verify the branch-circuit protection requirements before swapping.

What is 5SL6402-7's listed depth?

Overall depth is 76 mm; installation depth (behind the panel) is 70 mm.

What compliance documentation does Siemens provide for 5SL6402-7?

The breaker is certified to IEC 60898 and IEC 60947-2. It is halogen-free and silicon-free, which supports RoHS/REACH compliance. Siemens typically provides a declaration of conformity with the shipment; request it at time of order if needed for your quality documentation.

MPN
5SL6402-7