Siemens 5SL6402-7RC — Miniature Circuit Breakers (MCB)

Siemens 5SL6402-7RC SENTRON MCB, 2A 4P C-Curve, 7.5 kA

MPN5SL6402-7RC
Active

Siemens SENTRON 5SL6402-7RC miniature circuit breaker, 2 A, 4-pole, C characteristic, 7.5 kA breaking capacity per EN 60898, 4 MW width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6402-7RC — Ratings
ParameterValue
Overvoltage categoryIII
5SL6402-7RC — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SL6402-7RC is a SENTRON miniature circuit breaker rated 2 A with a C tripping characteristic, 4-pole construction, and a 7.5 kA breaking capacity according to EN 60898. Designed for residential and infrastructure final-distribution boards, it protects branch circuits against overload and short-circuit faults.

The C characteristic means the magnetic trip fires at 5 to 10 times rated current (10 to 20 A for this 2 A unit), making it suitable for circuits with moderate inrush — think lighting banks, small transformers, or resistive loads. Rated for 415 V AC three-phase (440 V max) and 250 V single-phase, with a 72 V DC maximum for DC-side applications. Power loss runs 1.25 W per pole in hot operating state at rated current — 5 W total for the 4-pole assembly. That matters for thermal derating inside a crowded enclosure; keep the ambient below 75 °C and allow natural convection around the 4-MW footprint. The breaker accepts supplementary devices (shunt trip, auxiliary contacts, undervoltage release) via the accessory slot, so you can add remote tripping or status feedback without replacing the base unit. Sealable terminals are standard — useful for utility-metering or tamper-evident installations.

The 5SL6402-7RC carries an active lifecycle status from Siemens. It is a current-production part in the SENTRON 5SL series, not subject to phase-out or last-time-buy. For BOM planning, this means no requalification risk from an imminent EOL notice.

Any mounting position is permitted — horizontal, vertical, or flat — so panel layout is flexible.

Environmental and compliance profile

Vibration resistance per IEC 60068-2-6 is not specified for this variant, so avoid mounting directly on high-vibration machinery without additional damping.

Frequently asked questions

What is the breaking capacity of 5SL6402-7RC?

The breaking capacity is 7.5 kA according to EN 60898 at 415 V AC. This is the maximum fault current the breaker can safely interrupt under standard test conditions.

What is the width of 5SL6402-7RC in modular units?

It occupies 4 modular width units, which is 72 mm. The installation depth behind the panel is 70 mm.

Where can I buy 5SL6402-7RC?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SL6402-7RC