Skip to main content
Siemens 5SL6404-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SL6404-7CC SENTRON MCB, 4-pole C 4A, 6kA

MPN5SL6404-7CC
Active

Siemens SENTRON 5SL6404-7CC, miniature circuit breaker, 4-pole, C characteristic, 4 A rated, 6 kA breaking capacity per EN 60898, 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6404-7CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6404-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC4 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
5SL6404-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SL6404-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6404-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL6404-7CC is a 4-pole miniature circuit breaker with a C tripping characteristic, rated 4 A at 400 V AC and a breaking capacity of 6 kA per EN 60898. The C-curve means it holds through moderate inrush (typically 5–10× rated current) before tripping, which suits mixed loads with some motor or transformer starting current. Rated current derates with ambient temperature: 3.82 A at 40 °C, 3.63 A at 50 °C, 3.53 A at 55 °C — if your panel runs warm, you need to account for that or the breaker may nuisance-trip.

Deployment context — panel integration

Designed for DIN-rail mounting in residential and infrastructure distribution boards. The sealable design (padlockable handle) allows lockout/tagout isolation — if it's not locked, it's not safe. Halogen-free and silicon-free construction means it won't release corrosive gases in a fire, which matters for ventilation-constrained enclosures or sensitive electronics sharing the same cabinet. Touch protection on the terminals reduces arc-flash risk during troubleshooting.

Frequently asked questions

What is the depth of 5SL6404-7CC?

The overall depth is 76 mm; the installation depth behind the panel face is 70 mm.

What is the width of 5SL6404-7CC?

72 mm, which corresponds to 4 modular width units on a standard DIN-rail panel.

MPN
5SL6404-7CC