Siemens 5SL6410-7MB — 4-Pole MCB (DIN Rail)

Siemens 5SL6410-7MB SENTRON MCB, 4P, C-curve, 10 A, 6 kA

MPN5SL6410-7MB
Active

Siemens SENTRON 5SL6410-7MB miniature circuit breaker, 4-pole, C-curve, 10 A rated, 6 kA breaking capacity per EN 60898, 400 V AC, 4 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6410-7MB — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6410-7MB — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SL6410-7MB — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL6410-7MB — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6410-7MB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6410-7MB — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.2 W

Product details

SENTRON 5SL6410-7MB — 4-pole C-curve MCB, 10 A, 6 kA

The Siemens SENTRON 5SL6410-7MB is a 4-pole miniature circuit breaker with C-curve tripping characteristic, rated 10 A at 400 V AC and a breaking capacity of 6 kA per EN 60898.

In a panel with multiple breakers ganged together, derating may apply; the 1.2 W power loss per pole adds up across four poles (4.8 W total) and should be considered in enclosure thermal calculations. For installations where the available fault current exceeds 6 kA (e.g., close to a transformer), a higher-rated upstream device or a current-limiting MCB is needed. The 5SL6410-7MB carries Energy Limitation Class 3, meaning it limits let-through energy effectively for most final-circuit faults. Rated voltage 400 V AC for multi-phase operation, with a maximum of 440 V AC. Single-phase operation is rated at 250 V AC. The breaker is designed for AC circuits only; for DC applications the maximum DC voltage is 72 V, which limits its use to low-voltage DC subcircuits. Install inside a panel or enclosure that provides the required environmental sealing. The breaker is sealable to prevent tampering after commissioning.

The 4-module-width body (72 mm wide,) occupies four 18 mm slots. Mounting position is any, which simplifies layout in crowded enclosures.

Frequently asked questions

What is the breaking capacity of 5SL6410-7MB?

The breaking capacity is 6 kA per EN 60898 at 400 V AC. This is the maximum fault current the breaker can safely interrupt.

What is the tripping characteristic of 5SL6410-7MB?

It has a C-curve characteristic, tripping between 5 and 10 times rated current. This suits mixed resistive and moderate inductive loads like lighting and socket outlets.

Where can I buy 5SL6410-7MB and how is it quoted?

The 5SL6410-7MB is sourced through the Siemens authorized channel. It is quoted to order against an RFQ; availability and current pricing are confirmed at quote time.

MPN
5SL6410-7MB