Siemens 5SL6416-6 SENTRON MCB, B-Curve 16A 4P 6kA

MPN5SL6416-6
Active

Siemens SENTRON 5SL6416-6, 4-pole miniature circuit breaker, B-curve, 16 A rated at 400 V AC, 6 kA breaking capacity per EN 60898 and IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6416-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6416-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC16 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
5SL6416-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-26 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SL6416-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6416-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity

Product details

The Siemens 5SL6416-6 is a 4-pole SENTRON miniature circuit breaker with B-curve tripping characteristic, rated 16 A at 400 V AC. Breaking capacity is 6 kA per both EN 60898 and IEC 60947-2 — enough for most residential and light commercial sub-distribution boards.

Temperature derating matters

At 40 °C it derates to 15.23 A, at 45 °C to 14.88 A, and at 55 °C to 13.99 A. Plan the load side accordingly so the breaker doesn't nuisance-trip on a hot day.

Frequently asked questions

What is the breaking capacity of the 5SL6416-6?

6 kA per both EN 60898 and IEC 60947-2, at 400 V AC.

Where can I buy the 5SL6416-6 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current availability and pricing.

What compliance documentation does Siemens provide for the 5SL6416-6?

The breaker carries IP20 protection (with connected conductors), is halogen-free and silicon-free, and is rated for overvoltage category III, pollution degree 2. It is designed for residential buildings and infrastructure per the manufacturer's suitability listing.