Siemens 5SL6416-7BB — 4-Pole MCB (DIN Rail)

Siemens 5SL6416-7BB SENTRON MCB, 4P C 16A 6kA 400V

MPN5SL6416-7BB

Siemens SENTRON 5SL6416-7BB miniature circuit breaker, 4-pole, C tripping characteristic, 16 A rated current, 6 kA breaking capacity at 400 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6416-7BB — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6416-7BB — Ratings
ParameterValue
Number of poles4
Rated current (In), AC16 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
5SL6416-7BB — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-26 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SL6416-7BB — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6416-7BB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6416-7BB — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

At 30 °C ambient the breaker holds a full 16 A. At 40 °C it derates to 15.15 A, at 45 °C to 14.72 A, and at 55 °C to 13.79 A. If your panel runs warm — say near a transformer or a row of contactors — size the load to the derated value at your actual ambient, not the 30 °C number. Mounting position is any — vertical, horizontal, or upside-down — so it fits tight enclosures without worrying about orientation. Terminal protection is IP20 with conductors connected; keep bare fingers away from the live terminals.

Frequently asked questions

What is the breaking capacity of 5SL6416-7BB?

6 kA per EN 60898 and also 6 kA per IEC 60947-2 at 400 V AC. That covers standard residential and commercial fault levels.

What is the difference between 5SL6416-7BB and 5SL6550-7BB?

The 5SL6550-7BB is a 4-pole C-curve breaker rated 50 A instead of 16 A. Both share the same 6 kA breaking capacity, 400 V AC rating, and 4-module width. The 5SL6416-7BB is sized for smaller branch circuits; the 50 A version handles heavier loads like sub-feeds.