Siemens 5SL6416-7MB — 4-Pole MCB (DIN Rail)

Siemens 5SL6416-7MB SENTRON MCB, 4P C 16A 6kA 400V

MPN5SL6416-7MB
Active

Siemens SENTRON 5SL6416-7MB miniature circuit breaker, 4-pole, C-curve, 16 A, 6 kA per EN 60898, 400 V AC, 4 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6416-7MB — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6416-7MB — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SL6416-7MB — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL6416-7MB — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6416-7MB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6416-7MB — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.7 W

Product details

For higher fault-current environments (e.g., industrial distribution boards), check whether the installation requires IEC 60947-2 ratings — this unit carries only the EN 60898 rating. The 400 V AC rated voltage covers standard three-phase supplies; single-phase operation is rated at 250 V. DC operation is limited to 72 V maximum, so it is not a primary choice for DC battery banks or PV strings. The 1.7 W power loss per pole in hot operating state at rated current adds up to 6.8 W total for the 4-pole unit — negligible for most enclosures, but worth noting if the panel is densely packed and ambient temperature is already high.

Snap-on DIN rail mounting, any position. Sealable, halogen-free, silicon-free.

Frequently asked questions

Where can I buy 5SL6416-7MB and how do I get a price?

The 5SL6416-7MB is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the difference between 5SL6416-7MB and 5SL4363-7?

The 5SL4363-7 is a 3-pole unit with a higher breaking capacity of 10 kA per EN 60898 and IEC 60947-2, versus the 4-pole 5SL6416-7MB at 6 kA. The 5SL4363-7 also has a higher per-pole power loss (5 W vs 1.7 W). The 5SL6416-7MB will not drop into a panel wired for the 3-pole 5SL4363-7 without adding a neutral pole and verifying the fault-current rating.