Skip to main content
Siemens 5SL6416-7RC — 4-Pole MCB (DIN Rail)

Siemens 5SL6416-7RC SENTRON MCB, 16A 4P C-Curve 7.5kA

MPN5SL6416-7RC
Active

Siemens SENTRON 5SL6416-7RC, miniature circuit breaker, 16 A, 4-pole, C characteristic, 7.5 kA breaking capacity per EN 60898, 415 V AC, 72 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6416-7RC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6416-7RC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SL6416-7RC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation classNo
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL6416-7RC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6416-7RC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6416-7RC — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.7 W

Product details

Siemens SENTRON 5SL6416-7RC — 16 A, 4-Pole MCB, C-Curve

The Siemens 5SL6416-7RC is a 4-pole miniature circuit breaker rated 16 A with a C tripping characteristic, housed in a 72 mm wide (4-module) SENTRON package.

At 72 mm wide (4 modular width units), 90 mm tall, and 76 mm deep, the 5SL6416-7RC occupies four standard DIN-rail positions.

The degree of pollution is rated 2 (non-conductive pollution only), and overvoltage category III suits fixed-installation distribution boards. Lifecycle status is Active per the manufacturer — this is a current-production part, not subject to phase-out.

In a typical residential or light commercial panel, the upstream main breaker or fuse must have a higher breaking capacity (often 10 kA or 25 kA) to ensure selectivity — the 5SL6416-7RC clears its own faults without the upstream device opening. For systems with higher prospective fault current (e.g., near a transformer), a breaker with a 10 kA or 15 kA rating would be needed upstream. The 4-pole design with a 72 V DC maximum rating on each pole means it can also be used in DC circuits up to 72 V, though the AC application is primary. The 10 000 mechanical operating cycles typical service life is standard for this class — adequate for normal switching, not intended for frequent motor starting duty (that calls for a contactor).

Frequently asked questions

What is the breaking capacity of the 5SL6416-7RC?

The rated breaking capacity is 7.5 kA per EN 60898 at 415 V AC. This is the maximum fault current the breaker can safely interrupt under standard test conditions.

Will the 5SL6416-7RC fit a panel designed for the 5SL4363-7?

The 5SL6416-7RC is 72 mm wide (4 modules), while the 5SL4363-7 is 54 mm wide (3 modules). The 5SL6416-7RC will not drop into a panel wired for the 3-pole 5SL4363-7 without additional DIN-rail space and rewiring for the fourth pole.

Where can I buy the 5SL6416-7RC?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What compliance documentation does Siemens provide for the 5SL6416-7RC?

The 5SL6416-7RC carries an IP20 rating, is halogen-free and silicon-free, and is rated for overvoltage category III with pollution degree 2. Standard documentation includes the EN 60898 breaking capacity certification and the manufacturer's declaration of conformity.

MPN