Siemens 5SL6425-7RC — 4-Pole MCB (DIN Rail)

Siemens 5SL6425-7RC SENTRON MCB, 25A 4P C-Curve, 7.5kA

MPN5SL6425-7RC
Active

Siemens SENTRON 5SL6425-7RC, miniature circuit breaker, 4-pole, 25 A, C characteristic, 7.5 kA breaking capacity per EN 60898, 415 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6425-7RC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6425-7RC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SL6425-7RC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation classNo
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL6425-7RC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6425-7RC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6425-7RC — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.2 W

Product details

The Siemens 5SL6425-7RC is a SENTRON miniature circuit breaker (MCB) rated 25 A, 4-pole, with a C tripping characteristic and a 7.5 kA breaking capacity per EN 60898 at 415 V AC. It is designed for residential and infrastructure branch-circuit protection — think distribution boards in apartment blocks, light commercial, or utility sub-mains where the fault level stays under 7.5 kA. On the DC side it is rated up to 72 V, so it can also serve as a DC branch protector in a telecom or solar combiner box fed from a 48 V or 60 V bus.

The 7.5 kA breaking capacity per EN 60898 is the standard for most residential and light commercial distribution boards in Europe and Asia — it safely interrupts a fault up to 7.5 kA at 415 V AC without welding the contacts or cascading damage upstream. If your installation's prospective short-circuit current (PSCC) at the breaker terminals exceeds 7.5 kA, step up to a 10 kA or 15 kA rated MCB from the same SENTRON family. For a 4-pole breaker that is 8.8 W total dissipated inside the enclosure — negligible for a single unit, but worth summing if the board packs twenty of these in a sealed cabinet with no forced ventilation. That is fine for a distribution board seeing a few operations per year; for a frequent-switching application (e.g., a lighting contactor replacement), use a dedicated contactor instead.

Frequency range is 50/60 Hz — no derating needed for 50 Hz vs 60 Hz mains.

Frequently asked questions

Will 5SL6425-7RC drop into a panel specified around 5SL4363-7?

No — the 5SL6425-7RC is 4-pole (72 mm wide, 4 MW) while the 5SL4363-7 is 3-pole (54 mm wide, 3 MW). The depth (76 mm) and height (90 mm) are identical, so the only dimensional difference is the extra pole width. A panel designed for a 3-pole unit has no space for the fourth pole without a busbar or rail modification.

What compliance documentation does Siemens provide for 5SL6425-7RC?

The part is halogen-free and silicon-free. It carries overvoltage category III and pollution degree 2 ratings per IEC/EN standards. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration at quote time.