Siemens 5SL6501-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SL6501-7CC SENTRON MCB, 1P+N, C-curve, 1 A, 6 kA

MPN5SL6501-7CC
Active

Siemens SENTRON 5SL6 series, miniature circuit breaker, 1P+N, C-curve, 1 A rated, 6 kA breaking capacity per EN 60898, 230 V AC, 2 module widths (36 mm), halogen-free, sealable.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6501-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL6501-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Overvoltage category3
5SL6501-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SL6501-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL6501-7CC is a SENTRON miniature circuit breaker rated 1 A with a C tripping characteristic, 1P+N poles, and a 6 kA breaking capacity per EN 60898. It's built for 230 V AC single-phase circuits in residential and infrastructure panels — think lighting, general-purpose outlets, or control transformers where the inrush isn't brutal but you still need magnetic trip above 5–10× rated current.

The 1P+N configuration switches both phase and neutral, with the neutral pole switching but not protecting (overcurrent sensing on the phase only). That's standard for single-phase final subcircuits where you want isolation on both conductors. Terminal capacity accepts 0.75 to 25 mm² solid or stranded copper, with a tightening torque of 2.5 to 3 N·m — standard screw terminals, no special tooling.

Deployment context

The C-curve thermal element compensates across that range, but expect some shift in the thermal trip point near the extremes — standard for all thermal-magnetic MCBs.

Frequently asked questions

What is the breaking capacity of the 5SL6501-7CC?

6 kA rated breaking capacity per EN 60898 at 230 V AC. That's the standard interrupting rating for this class of residential/infrastructure MCB.

What conductor sizes does the 5SL6501-7CC accept?

Solid or stranded copper from 0.75 mm² up to 25 mm². The screw terminals require a tightening torque of 2.5 to 3 N·m.

Where can I buy the 5SL6501-7CC and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
5SL6501-7CC