Skip to main content
Siemens 5SL6502-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SL6502-7CC SENTRON MCB, 1P+N, C-curve, 2 A, 6 kA

MPN5SL6502-7CC
Active

Siemens SENTRON 5SL series, 5SL6502-7CC miniature circuit breaker, 1P+N, C-curve, 2 A, 6 kA, 230 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6502-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL6502-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Overvoltage category3
5SL6502-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SL6502-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL6502-7CC is a 1P+N miniature circuit breaker with a C tripping characteristic, rated 2 A at 230 V AC and a breaking capacity of 6 kA per EN 60898. It switches the neutral conductor and is designed for residential and infrastructure branch-circuit protection.

The 2 A C-curve is a fast magnetic trip — it clears short-circuits at 5 to 10 times rated current (10–20 A). That suits lighting and small resistive loads where inrush is moderate; a B-curve would nuisance-trip on the same circuit, while a D-curve might let a fault ride through too long. In a panel with a higher prospective fault current, you'd need a current-limiting upstream breaker or a higher-rated MCB. That's standard for single-phase final circuits where the neutral must be disconnected for isolation. The 2-module width (36 mm) fits standard DIN-rail enclosures.

Screw terminals accept 0.75–25 mm² solid or stranded copper — no ferrule needed for the larger sizes, but a torque driver set to 2.5–3 N·m is recommended to avoid terminal damage. Halogen-free and silicon-free construction meets low-smoke material requirements for public-building installations.

Frequently asked questions

What are the key ratings of the 5SL6502-7CC?

Rated 2 A at 230 V AC, C-curve, 6 kA breaking capacity per EN 60898, 1P+N poles, 2-module width (36 mm).

Where can I buy the 5SL6502-7CC?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will the 5SL6502-7CC drop into a panel specified around the 5SL6016-7KL?

Both are 1P+N SENTRON 5SL series MCBs on the same DIN-rail footprint and terminal range, but the 5SL6502-7CC is a 2 A C-curve while the 5SL6016-7KL is a different rating — verify the branch-circuit ampacity before swapping.