Skip to main content
Siemens 5SL6504-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SL6504-7CC SENTRON MCB, 1P+N, C-curve, 4 A, 6 kA

MPN5SL6504-7CC
Active

Siemens SENTRON 5SL6504-7CC, miniature circuit breaker, 1P+N, C-curve, 4 A, 230 V AC, 6 kA per EN 60898, 2 MW wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6504-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL6504-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SL6504-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6504-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

SENTRON 5SL6504-7CC — 4 A C-curve MCB, 1P+N, 6 kA

The Siemens 5SL6504-7CC is a SENTRON miniature circuit breaker rated 4 A at 230 V AC with a C-curve trip characteristic and a 6 kA breaking capacity certified to EN 60898. It switches both line and neutral (1P+N) in a 2-module-width (36 mm) housing, with neutral conductor switching built in — no separate isolator needed for the neutral pole. The C-curve means the magnetic trip fires at 5 to 10 times rated current (20–40 A for this 4 A unit), making it the standard choice for mixed resistive and moderate inductive loads in residential and light commercial distribution boards — lighting, general-purpose sockets, small appliances. It is not intended for motor starting duty (where a D-curve or motor-protective breaker would be specified). Suited for fixed-installation sub-distribution where prospective short-circuit current stays under 6 kA.

IP20 with connected conductors. Terminal touch protection is fitted as standard. Energy limitation class 3 means the let-through energy (I²t) is low enough to protect downstream wiring and loads under fault conditions — a coordination consideration when selecting backup fuses or an upstream MCCB.

Vibration resistance tested to IEC 60068-2-6 at 50 m/s² over 25 to 150 Hz. These ratings cover unheated utility rooms, outdoor-adjacent enclosures, and transport vibration. The breaker carries no explicit UL/CSA listing in the evidence; compliance documentation should be verified against the specific project jurisdiction. The EN 60898 certification is the primary approval for IEC-market installations.

Frequently asked questions

Will 5SL6504-7CC drop into a panel specified around 5SL6016-7KL?

The 5SL6504-7CC is 2 MW wide (36 mm) versus the 5SL6016-7KL at 1 MW (18 mm), so it occupies one extra module slot. Both are 76 mm deep, 90 mm tall, and share the same DIN rail footprint, terminal design, and IP20 rating. The physical swap is straightforward if the panel has the spare width; the wiring and neutral switching function are identical.

What is the width of 5SL6504-7CC?

36 mm, which is 2 modular width units (MW) on a standard DIN rail.

Where can I buy 5SL6504-7CC?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
5SL6504-7CC