Skip to main content
Siemens 5SL6506-6YA — 1-Pole MCB (DIN Rail)

Siemens 5SL6506-6YA SENTRON MCB, B Curve, 6A, 1P+N, 6kA

MPN5SL6506-6YA

Siemens SENTRON 5SL6506-6YA miniature circuit breaker, 1P+N, B characteristic, 6 A rated, 6 kA breaking capacity per EN 60898, 230 V AC, 2 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6506-6YA — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL6506-6YA — Electrical & Protection
ParameterValue
Tripping characteristic classB
Energy limitation class3
Overvoltage categoryIII
5SL6506-6YA — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6506-6YA — Environmental
ParameterValue
IP protection classIP20 with distribution board cover
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SL6506-6YA SENTRON MCB — B Curve, 6 A, 1P+N, 6 kA

The Siemens 5SL6506-6YA is a SENTRON miniature circuit breaker (MCB) with a B tripping characteristic, rated 6 A at 230 V AC, single-pole plus neutral (1P+N), and a 6 kA breaking capacity per EN 60898. This 6 A rating suits lighting circuits, small appliance feeds, and control transformers in a panel.

Rated 6 A at both AC and 30 °C ambient. At 40 °C the continuous current derates to 0.93 A — that is a steep drop, so if the breaker shares a 40 °C enclosure with other heat sources, size up. At 45 °C the rating recovers to 5.4 A, which suggests the 0.93 A figure may be a worst-case condition; still, plan for the lower number if your panel runs warm. The unit is sealable (provision for a lockout tag or seal wire) and halogen-free / silicon-free, which matters for clean-room or high-reliability environments where outgassing is a concern.

Snap-on DIN-rail mount, any orientation. Depth is 76 mm (installation depth 70 mm), width 36 mm (2 MW), height 90 mm. The IP20 rating applies only with the distribution board cover fitted — the breaker itself is not finger-safe without the enclosure door closed. No supplementary devices can be installed on this unit.

Frequently asked questions

What is the difference between the 5SL6506-6YA and the 5SL6006-7?

The 5SL6006-7 is a C-curve 6 A MCB in a 1 MW (18 mm) width, versus the B-curve 2 MW (36 mm) 5SL6506-6YA. The 5SL6006-7 also accepts supplementary devices (auxiliary switches, shunt trips), which the 5SL6506-6YA does not. Both are 6 kA rated, but the trip curve and add-on capability are the deciding factors.

MPN
5SL6506-6YA