Siemens 5SL6506-7 SENTRON MCB, 1P+N, 6A, C-Curve, 6kA

MPN5SL6506-7
Active

Siemens SENTRON 5SL6 series miniature circuit breaker, 1P+N, 6 A, C-curve, 6 kA per EN 60898, 230 V AC, 2 MW width.

$9.91Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6506-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL6506-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SL6506-7 — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6506-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what the ratings mean

The Siemens 5SL6506-7 is a SENTRON 5SL6-series miniature circuit breaker (MCB) — 1P+N, 6 A rated, C-curve trip characteristic, breaking 6 kA per EN 60898 and IEC 60947-2 at 230 V AC. The C-curve (trips between 5× and 10× rated current) is the standard choice for general-purpose branch circuits feeding resistive and moderate inductive loads — lighting, receptacles, small appliances — in residential and light-commercial panels. The 6 kA breaking capacity means it can safely interrupt a fault current up to that level at the rated voltage, which covers the vast majority of domestic and infrastructure service-entrance applications.

Panel fit and integration

Snaps onto DIN rail (any mounting position), occupies 2 modular width units (36 mm wide). Depth is 76 mm, installation depth 70 mm — standard for the SENTRON 5SL6 family, so it aligns with the busbar and enclosure backplane without interference. The 1P+N design switches the line conductor and switches the neutral; the neutral pole is not protected but is switched with the line, which is common for single-phase final circuits in many markets. Sealable with a lead seal (provision on the toggle) for panel builders who need tamper evidence. Halogen-free and silicon-free construction matters if the breaker sits in a plenum or clean-room environment.

Frequently asked questions

What is the breaking capacity of the 5SL6506-7?

6 kA per both EN 60898 and IEC 60947-2 at 230 V AC. That is the standard interrupting rating for residential and light-commercial final circuits.

Will the 5SL6506-7 drop into a panel specified for the 5SL4363-7?

No — the 5SL4363-7 is a 3-pole (3P) breaker at 400 V AC, 54 mm wide (3 MW). The 5SL6506-7 is 1P+N, 36 mm wide (2 MW), 230 V AC. The busbar arrangement, voltage rating, and DIN space allocation are different; rewiring would be required.

Where can I buy the 5SL6506-7?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN