Siemens 5SL6506-7CC — 1-Pole MCB (DIN Rail)

Siemens 5SL6506-7CC SENTRON MCB, 1P+N, C-curve, 6 A, 6 kA

MPN5SL6506-7CC
Active

Siemens SENTRON 5SL6506-7CC, miniature circuit breaker, 1P+N, 2-pole, C-curve, 6 A, 6 kA breaking capacity per EN 60898, 230 V AC, 2 MW units wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6506-7CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL6506-7CC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SL6506-7CC — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6506-7CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL6506-7CC is a SENTRON miniature circuit breaker (MCB) — a 1P+N, 2-pole unit with a C-curve trip characteristic, rated 6 A at 230 V AC and a 6 kA breaking capacity per EN 60898. The 6 kA rating is the standard fault-interruption level for most domestic distribution boards in Europe. That's a standard SENTRON 5SL-series footprint; it drops into any panel already kitted with that family.

At 40 °C it derates to 5.66 A; at 50 °C to 5.29 A; at 55 °C to 5.1 A. That's the number to use for a real load calculation, not the 30 °C figure.

Sealable, halogen-free, silicon-free. Touch protection is included on the terminals. Neutral conductor switching is built in (1P+N design), so the neutral pole opens and closes with the phase. That's required in some regional wiring codes and useful for full isolation on the load side.

Frequently asked questions

What is the breaking capacity of 5SL6506-7CC?

6 kA per EN 60898 at 230 V AC. That's the standard fault-interruption rating for domestic and light commercial distribution boards.

Will 5SL6506-7CC drop into a panel specified for 5SL6550-7BB?

Both are SENTRON 5SL-series MCBs with the same 2 MW (36 mm) DIN-rail footprint, same depth and height. The 5SL6506-7CC is a C-curve 6 A 1P+N unit; the 5SL6550-7BB is a different rating/curve variant. If the panel was designed for the 5SL6550-7BB, the 5SL6506-7CC will physically fit without rewiring, but the electrical ratings (current, curve, poles) must match the circuit design.

How do I get pricing and availability for 5SL6506-7CC?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and stock levels are confirmed at quote time.

MPN
5SL6506-7CC