The 5SL6510-6YA: The B-curve trips between 3 and 5 times rated current (30–50 A magnetic release). If your fault level exceeds 6 kA, you need a higher-rated MCB or a current-limiting upstream device. The 1P+N design switches both line and neutral, which is required in some national wiring regulations (e.g., UK, Australia) for final circuits. The neutral pole is not protected — it opens and closes with the line pole but has no overcurrent release. That saves a pole width compared to a 2-pole MCB while still providing disconnection of both conductors. Temperature derating is built into the spec: full 10 A at 30 °C, 9.2 A at 45 °C, and a sharp drop to 0.95 A at 40 °C — that last figure looks like a data anomaly (likely a typo for a different variant), so treat the 45 °C value as the practical derated limit. Ambient temperature inside a crowded enclosure can easily hit 45 °C; plan for 9.2 A continuous load in that scenario.

Siemens 5SL6510-6YA SENTRON MCB, 1P+N, B-Curve, 10 A, 6 kA
MPN 5SL6510-6YA
Siemens SENTRON 5SL6510-6YA, miniature circuit breaker, 1P+N, B-characteristic, 10 A rated, 6 kA breaking capacity per EN 60898, 2 MW, 230 V AC.
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Poles | 2 |
| IP rating | IP20 |
| Depth | 76 mm |
| Width | 36 mm |
| Height | 90 mm |
| Energy limitation class | 3 |
Product details
5SL6510-6YA Datasheet
MPN
5SL6510-6YA