The 5SL6510-6YA: The B-curve trips between 3 and 5 times rated current (30–50 A magnetic release). If your fault level exceeds 6 kA, you need a higher-rated MCB or a current-limiting upstream device. The 1P+N design switches both line and neutral, which is required in some national wiring regulations (e.g., UK, Australia) for final circuits. The neutral pole is not protected — it opens and closes with the line pole but has no overcurrent release. That saves a pole width compared to a 2-pole MCB while still providing disconnection of both conductors. Temperature derating is built into the spec: full 10 A at 30 °C, 9.2 A at 45 °C, and a sharp drop to 0.95 A at 40 °C — that last figure looks like a data anomaly (likely a typo for a different variant), so treat the 45 °C value as the practical derated limit. Ambient temperature inside a crowded enclosure can easily hit 45 °C; plan for 9.2 A continuous load in that scenario.
Siemens 5SL6510-6YA SENTRON MCB, 1P+N, B-Curve, 10 A, 6 kA
MPN5SL6510-6YA
Siemens SENTRON 5SL6510-6YA, miniature circuit breaker, 1P+N, B-characteristic, 10 A rated, 6 kA breaking capacity per EN 60898, 2 MW, 230 V AC.
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Miniature circuit breaker |
| Brand name | SENTRON |
| Number of poles | 2 |
| Pole design | 1P+N |
| Application suitability | Residential buildings/infrastructure |
| Parameter | Value |
|---|---|
| Tripping characteristic class | B |
| Energy limitation class | 3 |
| Overvoltage category | III |
| Parameter | Value |
|---|---|
| Mounting position | any |
| Width | 36 mm |
| Height | 90 mm |
| Depth | 76 mm |
| Installation depth | 70 mm |
| Modular width units | 2 |
| Torque, min. | -40 °C |
| Torque, max. | 75 °C |
| Sealable | Yes |
| Parameter | Value |
|---|---|
| IP protection class | IP20 with distribution board cover |
| Pollution degree | 2 |
| Halogen-free | Yes |
| Silicone-free | Yes |
Product details
Frequently asked questions
What is the difference between the 5SL6510-6YA and the 5SL6516-6YA?
The 5SL6516-6YA is the same physical MCB (1P+N, B-curve, 6 kA, 2 MW) but rated 16 A instead of 10 A. Both share the same dimensions, breaking capacity, and temperature derating profile. The 5SL6510-6YA drops into a panel specified for the 16 A version without any rewiring — just swap the breaker if the load current allows.