Siemens 5SL6510-7BB — 1-Pole MCB (DIN Rail)

Siemens 5SL6510-7BB SENTRON MCB, 2-pole C-curve 10 A 6 kA

MPN5SL6510-7BB

Siemens SENTRON 5SL series, miniature circuit breaker 5SL6510-7BB, 2-pole 1P+N, C-curve, 10 A rated, 6 kA breaking capacity, 230 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6510-7BB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL6510-7BB — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SL6510-7BB — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6510-7BB — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SL6510-7BB is a 2-pole miniature circuit breaker (MCB) with a 1P+N configuration — it switches the line and switches the neutral, which is a requirement in many residential and light-commercial distribution boards where the neutral must be isolated when the breaker is off. Rated 10 A at 230 V AC with a C-curve tripping characteristic, meaning it is designed for moderate inrush loads like small motors, lighting banks, and transformer primaries — the magnetic trip threshold sits at 5 to 10 times rated current, so it holds through a short motor start but clears a hard fault fast. Breaking capacity is 6 kA per EN 60898 and IEC 60947-2, which covers the typical prospective fault level at the sub-distribution level in most commercial and residential panels — no need to uprate unless you are close to a large transformer.

Occupies 2 modular width units (36 mm) on a DIN rail, with a 76 mm depth that clears most standard enclosure gland plates and busbar shrouds — the 70 mm installation depth means it fits into shallow backboxes without forcing the door. Rated IP20 with connected conductors — that is the standard for inside a distribution board; no special sealing required as long as the enclosure door is closed.

Thermal derating — the number that matters for real loads

The 10 A rating holds at 30 °C ambient; at 40 °C it derates to 9.24 A, at 45 °C to 8.8 A, and at 55 °C to 7.96 A — if the panel sits in a hot machine room or a sun-exposed cabinet, size the upstream load accordingly or step to the next higher amp rating. Ambient conditions include periodic exposure to +55 °C with up to 95 % humidity — this MCB is rated for the condensation-prone environments you find in tropical installations or unheated electrical rooms.

Designed to EN 60898 and IEC 60947-2, with overvoltage category III and pollution degree 2 — suitable for fixed-installation distribution boards in residential and infrastructure buildings.

MPN
5SL6510-7BB