Skip to main content
Siemens 5SL6532-6YA — 1-Pole MCB (DIN Rail)

Siemens 5SL6532-6YA SENTRON MCB, 1P+N, B, 32 A, 6 kA

MPN5SL6532-6YA

Siemens SENTRON 5SL6532-6YA miniature circuit breaker, 1-pole+N, B characteristic, 32 A, 6 kA interrupting capacity per EN 60898, 230 V AC, 2 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6532-6YA — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityResidential buildings/infrastructure
5SL6532-6YA — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SL6532-6YA — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6532-6YA — Environmental
ParameterValue
IP protection classIP20 with distribution board cover
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what it does

The Siemens 5SL6532-6YA is a SENTRON miniature circuit breaker (MCB) with a 1-pole+N design — it switches the live conductor and also breaks the neutral, which is required for single-phase final subcircuits in residential and light commercial distribution boards. Rated 32 A at 30 °C with a B tripping characteristic, it protects against overload and short-circuit up to 6 kA per EN 60898. The B curve means it trips at 3 to 5 times rated current, so it is sized for resistive and general-purpose loads where inrush is low — lighting, socket outlets, small appliances.

What the ratings mean for fit

The 32 A rating at 30 °C is the headline figure, but the derating curve matters: at 40 °C the breaker is rated 0.95 A (likely a data-entry anomaly for a 32 A device — the 45 °C figure of 29.44 A is the realistic derated value for this frame). If your panel ambient runs above 40 °C, expect to down-rate the circuit or step to a higher ampacity frame. The 6 kA breaking capacity per EN 60898 covers most domestic and light commercial fault levels; for industrial installations with higher prospective short-circuit current, you would need the IEC 60947-2 rating (not listed for this variant). Overvoltage category III and pollution degree 2 confirm it is rated for fixed-installation distribution boards, not for outdoor or wet locations.

Panel integration and mounting

Occupies 2 modular width units (36 mm) on a DIN rail. Installation depth is 70 mm, overall depth 76 mm — check gland-plate clearance if the enclosure is shallow. Mounting position is unrestricted, so it can be installed horizontally or upside-down without derating. The breaker is sealable (provision for a lead seal or lockout tag) and halogen-free / silicon-free, which matters for panels in clean-room or corrosive environments. IP20 with the distribution-board cover fitted — no touch protection on the terminals themselves, so the cover must be in place for live-work safety.

Frequently asked questions

Will the 5SL6532-6YA drop into a panel specified around the 5SL6516-6YA?

Yes — the 5SL6516-6YA is the 16 A version of the same 1P+N, B-curve, 6 kA frame. Same dimensions (76 mm depth, 36 mm width, 90 mm height), same mounting, same accessories. The only difference is the ampacity: 32 A vs 16 A. No rewiring or panel modification needed.

MPN
5SL6532-6YA