Siemens 5SL6540-7 — 1-Pole MCB (DIN Rail)

5SL6540-7 SENTRON MCB, 1P+N, C-curve, 40 A, 6 kA

MPN5SL6540-7
Active

Siemens SENTRON 5SL6540-7 miniature circuit breaker, 1P+N, C-curve, 40 A, 6 kA per EN 60898, 230 V AC, 2 MW, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SL6540-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityResidential buildings/infrastructure

Electrical & Protection

5SL6540-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII

Mounting & Connection

5SL6540-7 — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes

Environmental

5SL6540-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what it does

The Siemens SENTRON 5SL6540-7 is a 1P+N miniature circuit breaker (MCB) with a C tripping characteristic, rated 40 A at 230 V AC and a 6 kA breaking capacity per EN 60898. It switches the neutral conductor along with the line, so it's a single-module-width (2 MW) unit that fits standard DIN-rail distribution boards in residential and light commercial infrastructure.

What the ratings mean for fit

The C-curve means the magnetic trip activates at 5–10× rated current — designed for loads with moderate inrush like small motors, fluorescent lighting banks, or transformer-coupled circuits. At 40 A and 6 kA SCCR, it handles typical residential and light commercial fault levels; the same 6 kA rating applies under IEC 60947-2 for industrial panel applications where the standard demands it. Thermal derating is published: full 40 A at 30 °C ambient, 37.57 A at 40 °C, 36.8 A at 45 °C, and 33.61 A at 55 °C (–). If your panel ambient runs above 30 °C, size the upstream protection for the derated figure — the breaker will hold at its published curve, not the nameplate 40 A. Mechanical service life is 10,000 switching cycles — fine for a distribution board where the breaker is rarely operated, but not rated for frequent switching duty like a motor-disconnect application.

Panel fit and mounting

Width is 36 mm (2 modular units), depth 76 mm, height 90 mm, installation depth 70 mm. Snaps onto standard 35 mm DIN rail; mounting position is unrestricted. The housing is halogen-free and silicon-free — relevant for panels in clean-room or semiconductor-adjacent environments where outgassing is a concern. IP20 with connected conductors — protected against finger contact but not water ingress; install inside a sealed enclosure if washdown or outdoor exposure is expected. Overvoltage category III and pollution degree 2 cover fixed-installation distribution panels.

Frequently asked questions

What is the breaking capacity of 5SL6540-7?

6 kA per EN 60898 and also 6 kA per IEC 60947-2 at 230 V AC.

What is the width of 5SL6540-7 in modular units?

2 modular width units, which is 36 mm.

Does 5SL6540-7 switch the neutral?

Yes, it has neutral conductor switching in a 1P+N design.

Where can I buy 5SL6540-7 and get current pricing?

We source and quote this part to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response.

MPN
5SL6540-7