Skip to main content
Siemens 5SL6550-7 — 1-Pole MCB (DIN Rail)

Siemens 5SL6550-7 SENTRON MCB, 1P+N, C-curve, 50 A, 6 kA

MPN5SL6550-7
Active

Siemens SENTRON 5SL6550-7 miniature circuit breaker, 1P+N, C-curve, 50 A, 230 V AC, 6 kA breaking capacity per EN 60898 / IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SL6550-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure

Electrical & Protection

5SL6550-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII

Mounting & Connection

5SL6550-7 — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes

Environmental

5SL6550-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Integrator's spec recap — 5SL6550-7

The Siemens 5SL6550-7 is a SENTRON miniature circuit breaker (MCB) in a 1P+N configuration — one protected pole plus a switched neutral — with a C-curve trip characteristic rated 50 A at 230 V AC. Breaking capacity is 6 kA per both EN 60898 and IEC 60947-2, so it coordinates with downstream loads in residential and light commercial distribution boards where the prospective fault current stays under that threshold. The C-curve (rated 50 A) trips between 5× and 10× In, making it a standard choice for mixed resistive and moderate inductive loads — lighting circuits, small motor branch circuits, and general-purpose socket outlets — where inrush isn't severe enough to need a D-curve. Thermal derating is published: 46.97 A at 40 °C, 45 A at 45 °C, 42.01 A at 55 °C. If the panel ambient runs above 30 °C, size the upstream feeder for the derated figure, not the nameplate 50 A.

DIN-rail footprint and panel fit

Width is 36 mm (2 modular units), depth 76 mm, height 90 mm. Installation depth 70 mm. Mounts in any position on standard DIN rail. IP20 with conductors connected — suitable for enclosed distribution boards, not for wet or washdown locations. Sealable (tamper-evident cover available) and halogen-free / silicon-free construction — relevant for installations with strict off-gassing requirements (hospitals, clean rooms, data centers).

Compliance and documentation

Rated for overvoltage category III, pollution degree 2. Mechanical service life 10,000 operating cycles typical. Energy limitation class 3. The part carries approvals per EN 60898 and IEC 60947-2; the manufacturer provides RoHS, REACH, and CE declarations as standard for the SENTRON line.

Frequently asked questions

Where can I buy 5SL6550-7 and how do I get a price?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 5SL6550-7's listed depth?

Depth is 76 mm; installation depth is 70 mm.

What is 5SL6550-7's listed width?

Width is 36 mm, which corresponds to 2 modular width units on a standard DIN rail.

Will 5SL6550-7 drop into a panel specified around 5SL6550-7BB without rewiring?

Both are 1P+N SENTRON MCBs with the same 36 mm width, 76 mm depth, and C-curve trip — they share the same DIN-rail footprint and pole configuration, so a direct mechanical swap is possible. The difference is in the rating: 5SL6550-7 is 50 A; 5SL6550-7BB is a different current rating. Verify the branch-circuit ampacity before substituting.

What compliance documentation does Siemens provide for 5SL6550-7?

The manufacturer provides RoHS, REACH, and CE declarations as standard for the SENTRON line. The MCB is rated per EN 60898 and IEC 60947-2.

MPN
5SL6550-7