Siemens 5SL6550-7BB — 1-Pole MCB (DIN Rail)

Siemens 5SL6550-7BB SENTRON MCB, 2-pole C 50 A 6 kA

MPN5SL6550-7BB

Siemens SENTRON 5SL6 series, miniature circuit breaker, 2-pole 1P+N, C-curve, 50 A rated, 6 kA breaking capacity, 230 V AC, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6550-7BB — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityResidential buildings/infrastructure
5SL6550-7BB — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)6 kA
Energy limitation class3
Overvoltage categoryIII
5SL6550-7BB — Mounting & Connection
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL6550-7BB — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SL6550-7BB is a SENTRON 5SL6 miniature circuit breaker — 2-pole 1P+N configuration, C-curve trip characteristic, rated 50 A at 230 V AC with a 6 kA breaking capacity certified to both EN 60898 and IEC 60947-2. At 50 A this is a high-current single-pole-plus-neutral breaker for the Italian market variant (the -7BB suffix). The neutral pole is switched — the breaker opens both line and neutral when it trips, which matters for installations that require full isolation on a single module width. If your panel's SCCR is higher, you'd step up to the 5SY series or a higher-rated SENTRON variant.

Thermal derating — the number that actually governs the load

At 40 °C it derates to 46.19 A, at 45 °C to 44 A, and at 55 °C to 39.81 A. That's a 20 % drop from the nameplate at the top of the operating range. The C-curve's magnetic trip threshold (5–10× In) means a 50 A unit holds through 250–500 A inrush before instant tripping — fine for lighting banks, distribution subfeeds, and small transformer primaries. For a motor circuit with locked-rotor inrush above 500 A, you'd want a D-curve or a motor-protective breaker instead.

Panel fit and installation notes

Depth behind the panel face is 70 mm installation depth; overall depth including the front profile is 76 mm. Terminals accept solid and stranded copper up to 25 mm² (the 5SL6563-7BB peer confirms the range). Halogen-free and silicon-free construction — no outgassing concerns in clean environments or sealed enclosures. Sealable per the spec, which matters for utility-metering applications where tamper evidence is required. Ambient storage range -40 to +75 °C covers warehouse and transport extremes.

Frequently asked questions

When sourcing 5SL6550-7BB, what's the closest functional second-source — 5SL6563-7BB?

The 5SL6563-7BB is the closest functional sibling — same 2-pole 1P+N C-curve, same 6 kA breaking capacity, same 76×36 mm DIN footprint, but rated 63 A instead of 50 A. It drops into the same panel without rewiring.

What is 5SL6550-7BB's listed depth (76 mm) on this component line?

The overall depth is 76 mm; the installation depth behind the panel face is 70 mm. Width is 36 mm (2 modular units), height is 90 mm.