Skip to main content
Siemens 5SL6601-7 — 4-Pole MCB (DIN Rail)

Siemens 5SL6601-7 SENTRON MCB, 4P, 1 A, C-curve, 6 kA

MPN5SL6601-7
Active

Siemens SENTRON 5SL6 series, 5SL6601-7 miniature circuit breaker (MCB), 4-pole (3P+N), rated current 1 A AC, tripping characteristic C, breaking capacity 6 kA acc. to EN 60898 / IEC 60947-2, rated voltage 400 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6601-7 — Identification
ParameterValue
Type / order code5SL6
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6601-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC1 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)60 V
Voltage typeAC
Rated frequency50 Hz
5SL6601-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-26 kA
Overvoltage category3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL6601-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
SealableYes
5SL6601-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SL6601-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The 1 A rated current and C-curve mean this MCB is sized for protecting a low-current final circuit — think lighting strings, control transformers, or small signal loads — where the C characteristic allows a moderate inrush without nuisance tripping (5–10× rated current magnetic release). Rated voltage of 400 V AC matches three-phase line-to-line supply; maximum operating voltage of 440 V AC gives headroom for nominal 400 V networks with tolerance. Terminals accept solid or stranded conductors from 0.75 to 25 mm², tightened to 2.5–3 N·m. The 72 mm width corresponds to 4 width units on a standard DIN rail — the same footprint as four single-pole MCBs side by side.

Deployment context and environment

Rated for ambient temperatures of -25 to +45 °C and storage down to -40 °C, with periodic exposure up to +55 °C and 95% humidity. Mounting position is any, which simplifies panel layout. Halogen-free and silicon-free construction reduces toxic smoke emission in a fire and avoids silicone contamination in sensitive environments. Sealable to prevent tampering after commissioning.

MPN
5SL6601-7