Skip to main content
Siemens 5SL6602-7 — Miniature Circuit Breakers (MCB)

Siemens 5SL6602-7 SENTRON MCB, 4-Pole C 2A, 6kA

MPN5SL6602-7
Active

Siemens SENTRON 5SL6 series, miniature circuit breaker (MCB), 4-pole (3P+N), C-curve, 2 A, 6 kA breaking capacity, 400 V AC, 4 width units.

$24.13Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6602-7 — Ratings
ParameterValue
Overvoltage category3
5SL6602-7 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SL6602-7 is a 4-pole (3P+N) miniature circuit breaker from the SENTRON 5SL6 family, rated 2 A with a C tripping characteristic. The C-curve means it holds through moderate inrush — good for small motor or lighting loads that draw a short surge on start.

Energy limiting class 3 means it restricts let-through energy on a short circuit, which helps with downstream equipment coordination. Terminals accept solid or stranded copper from 0.75 mm² up to 25 mm², with a tightening torque of 2.5 to 3 N·m. That covers most branch-circuit wiring sizes you'd pair with a 2 A breaker — 1.5 mm² or 2.5 mm² is typical. The breaker is sealable and has touch protection on the terminals, which simplifies inspection sign-off.

Where it lives in the panel

Frequently asked questions

Who supplies 5SL6602-7 and how is it quoted for volume purchases?

This part is sourced through independent distribution channels and quoted to order against an RFQ. Volume pricing and lead time are confirmed at the time of quotation.

What is 5SL6602-7's listed depth?

Overall depth is 76 mm; installation depth is 70 mm, which is the dimension that matters for enclosure clearance behind the DIN rail.

What wire sizes does 5SL6602-7 accept?

Solid and stranded copper from 0.75 mm² up to 25 mm², terminated with a screw clamp at 2.5 to 3 N·m.

Will 5SL6602-7 drop into a panel specified around 5SL6606-7YA without rewiring?

Both are 4-pole (3P+N) SENTRON 5SL6 breakers on the same DIN-rail footprint, so the mechanical fit and terminal spacing are identical. The difference is the current rating — 5SL6602-7 is 2 A C-curve, while 5SL6606-7YA carries a higher rating. As long as the circuit load matches the 2 A rating, it's a direct swap with no rewiring.

What compliance documentation does Siemens provide for 5SL6602-7?

The breaker is designed to EN 60898 and IEC 60947-2, with overvoltage category 3. It is halogen-free and silicon-free. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration of compliance with the RFQ.

MPN
5SL6602-7