Skip to main content
Siemens 5SL6603-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SL6603-7CC SENTRON MCB, 3P+N, C-Curve, 3A, 6kA

MPN5SL6603-7CC
Active

Siemens SENTRON 5SL6603-7CC miniature circuit breaker, 400 V AC, 6 kA, 3-pole+N, C-curve, 3 A, 4 MWUs.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6603-7CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6603-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL6603-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL6603-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6603-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6603-7CC — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.3 W

Product details

The Siemens 5SL6603-7CC is a SENTRON miniature circuit breaker (MCB) rated 400 V AC with a 6 kA breaking capacity per EN 60898, in a 3-pole+N configuration with C-curve tripping characteristic at 3 A. It occupies 4 modular width units (72 mm) on a DIN rail, making it a direct fit for standard residential and infrastructure distribution boards where a switched neutral is required.

What the ratings mean for fit

The C-curve (tripping characteristic class C) means the breaker trips at 5 to 10 times rated current — suited for circuits with moderate inrush, like lighting banks or small motor loads, without nuisance tripping on startup. The 6 kA breaking capacity at 400 V AC (per EN 60898) tells you it can safely interrupt a fault current up to that level; for installations with higher prospective fault current, you'd need a breaker with a higher rating or upstream current-limiting device. The 3-pole+N design switches all three phases and the neutral, which is required in TN-S or TT systems where the neutral must be disconnected for isolation. The neutral pole is switched but not protected — overcurrent protection is on the phase poles only. Rated for overvoltage category III and pollution degree 2, this MCB is specified for fixed installations inside a distribution board — not for outdoor or wet locations. The IP20 rating (with connected conductors) confirms it's touch-safe only when installed in an enclosure.

Panel integration and mounting

Snap-on mounting to DIN rail, any position. Depth is 76 mm (70 mm installation depth), width 72 mm (4 MWUs). The 90 mm height is standard for SENTRON 5SL series, so it aligns with adjacent breakers and busbars in a distribution board. Sealable, halogen-free, silicon-free — suitable for installations with material restrictions (e.g., healthcare, marine). Supplementary devices (auxiliary switches, shunt trips, alarm contacts) can be installed on the right side — the product extension feature is supported, so you can add remote signaling or trip indication without replacing the breaker.

Frequently asked questions

What is the breaking capacity of 5SL6603-7CC?

The breaking capacity is 6 kA at 400 V AC, rated according to EN 60898. This is the standard residential/commercial interrupting rating for this SENTRON series.

Will 5SL6603-7CC drop into a panel specified for 5SL4363-7?

No — the 5SL6603-7CC is 4 MWUs wide (72 mm) versus 3 MWUs (54 mm) for the 5SL4363-7, and it includes a switched neutral pole (3P+N) that the 3-pole 5SL4363-7 lacks. The panel would need a wider DIN rail slot and neutral busbar connection.

Where can I buy 5SL6603-7CC?

This part is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time.

MPN
5SL6603-7CC