Siemens 5SL6606-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL6606-6 SENTRON MCB, 4P B-Curve 6A 6kA

MPN5SL6606-6
Active

Siemens SENTRON 5SL6606-6 miniature circuit breaker, 4-pole (3P+N), B-curve, 6 A rated, 6 kA breaking capacity per EN 60898, 400 V AC, 4 MW units, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6606-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6606-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
5SL6606-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-26 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL6606-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6606-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity

Product details

Siemens 5SL6606-6 SENTRON MCB — 4-pole B-curve 6 A for residential and infrastructure panels

The Siemens 5SL6606-6 is a 4-pole (3P+N) miniature circuit breaker from the SENTRON series, rated 6 A at 400 V AC with a B-curve tripping characteristic. It breaks fault currents up to 6 kA per EN 60898 and IEC 60947-2, making it a standard choice for final subcircuit protection in residential buildings and infrastructure installations where the B-curve's instantaneous trip threshold (3–5× In) suits lighting and general-purpose loads with low inrush. The 4-pole configuration includes a switched neutral (3P+N), so it isolates all live conductors on fault — important for TN and TT systems where neutral switching is required by local wiring rules. The neutral conductor switching function is built in, not an add-on accessory.

At 40 °C it derates to 5.64 A, at 45 °C to 5.52 A, and at 55 °C to 5.04 A. The breaker itself is rated for ambient up to 75 °C and down to -40 °C, with periodic humidity up to 95% at 55 °C.

It is halogen-free and silicon-free, sealable, and touch-protected. The product designation per IEC 81346-2 and DIN EN 61346-2 is F (protective device).

Frequently asked questions

What is the breaking capacity of 5SL6606-6?

6 kA per both EN 60898 and IEC 60947-2 at 400 V AC.

What is the width of 5SL6606-6 in modular units?

4 modular width units, which is 72 mm.

Where can I buy 5SL6606-6?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.