Skip to main content
Siemens 5SL6606-7 — 4-Pole MCB (DIN Rail)

Siemens 5SL6606-7 SENTRON MCB, 4P C-Curve 6A 6kA 400V AC

MPN5SL6606-7
Active

Siemens SENTRON 5SL series miniature circuit breaker, order code 5SL6606-7, 4-pole (3P+N), C-curve, 6 A rated current, 6 kA breaking capacity at 400 V AC, 4 MW width.

$24.13Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6606-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6606-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50 Hz
5SL6606-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-26 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL6606-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6606-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity
5SL6606-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SL6606-7 is a SENTRON 5SL series miniature circuit breaker (MCB) designed for residential and infrastructure branch-circuit protection. The breaking capacity is 6 kA per both EN 60898 and IEC 60947-2, so it can safely interrupt a fault up to 6 kA at 400 V AC without welding the contacts or cascading the fault upstream.

The part carries no official successor because it is still active. If a buyer is cross-referencing from an older Siemens 5SL variant or a competitor's 4-pole C-curve 6A MCB, the key fit checks are the 3P+N wiring (not 4-pole independent), the 6 kA breaking capacity at 400 V AC, and the 4 MW DIN-rail footprint. The neutral-switching feature is present on this unit, so it is a direct drop-in for panels that require a switched neutral.

Integration notes

The 4 MW (72 mm) width means it occupies four adjacent 18 mm slots — plan the enclosure fill accordingly. Terminal screws accept up to 25 mm² conductors for the incoming and outgoing circuits.

Frequently asked questions

What is the breaking capacity of 5SL6606-7?

The breaking capacity is 6 kA at 400 V AC, rated per both EN 60898 and IEC 60947-2. This means it can safely interrupt a short-circuit fault up to 6 kA without damage.

Where can I buy 5SL6606-7 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the difference between 5SL6606-7 and 5SL4120-7CC?

The 5SL6606-7 is a 4-pole (3P+N) C-curve 6A MCB. The 5SL4120-7CC is a different variant in the same 5SL family — the key difference is the rated current and pole configuration. The 5SL6606-7 switches the neutral; the 5SL4120-7CC may not. Check the specific ratings before substituting.

Does 5SL6606-7 switch the neutral?

Yes, the 5SL6606-7 is a 3P+N design with neutral conductor switching. The neutral pole opens and closes with the phase poles, which is required in some regional wiring codes and for TN-S systems.

What compliance documentation is available for 5SL6606-7?

The 5SL6606-7 is a Siemens SENTRON product with standard CE marking for the European market. It is designed to meet EN 60898 and IEC 60947-2. Specific RoHS, REACH, and UL documentation should be requested at quote time from the supplier.

MPN
5SL6606-7