Skip to main content
Siemens 5SL6608-7 — Miniature Circuit Breakers (MCB)

Siemens 5SL6608-7 SENTRON MCB, 4P C-8A 6kA, 400V AC

MPN5SL6608-7
Active

Siemens SENTRON 5SL6 series, 5SL6608-7 miniature circuit breaker, 4-pole (3P+N), C-curve 8 A, 6 kA breaking capacity per IEC 60898, 400 V AC, 72 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL6608-7 — Ratings
ParameterValue
Overvoltage category3
5SL6608-7 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SL6608-7 is a SENTRON 5SL6 miniature circuit breaker (MCB) — 4-pole, 3P+N configuration, rated 8 A at 400 V AC with a C tripping characteristic. It breaks fault currents up to 6 kA per EN 60898 and IEC 60947-2, which means it coordinates with standard residential and light commercial distribution boards without requiring an upstream fuse for fault levels up to that threshold. The 72 mm width (4 width units) fits standard DIN-rail enclosures; the 76 mm depth and 70 mm installation depth leave clearance for cover-mounted accessories.

Breaking capacity of 6 kA per both EN 60898 and IEC 60947-2 tells you the breaker can safely interrupt a short-circuit fault up to 6 kA at the rated voltage; if your available fault current exceeds that, you need an upstream current-limiting device or a higher-rated breaker. Overvoltage category 3 means it's rated for fixed-installation distribution panels, not for downstream equipment-level protection. Energy limiting class 3 indicates it limits let-through energy effectively, reducing stress on downstream wiring during a fault.

Installation and environment

Ambient temperature range -25 to +45 °C covers most indoor panel environments; storage range -40 to +75 °C covers shipping and warehousing. Terminals accept solid or stranded conductors from 0.75 to 25 mm² — sufficient for 8 A circuits using 1.5 mm² or 2.5 mm² wiring, and the upper range covers parallel feeds or larger tails. Tightening torque 2.5 to 3 N·m; use a torque screwdriver to avoid terminal damage or loose connections.

Frequently asked questions

Where can I buy 5SL6608-7 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What is 5SL6608-7's listed depth?

The depth is 76 mm; installation depth is 70 mm, which accounts for the DIN-rail clip and terminal projection.

What conductor sizes does 5SL6608-7 accept?

Solid and stranded conductors from 0.75 to 25 mm² are accepted per the terminal specification.

What compliance documentation does Siemens provide for 5SL6608-7?

The breaker carries designations per DIN EN 61346-2 and DIN EN 81346-2 (function F). It is rated per EN 60898 and IEC 60947-2. Halogen-free and silicon-free construction is confirmed. Specific RoHS/REACH/UL declarations should be requested with the RFQ.