Siemens 5SL6616-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL6616-6 SENTRON MCB, 3P+N, 16A, B Curve, 6kA

MPN5SL6616-6
Active

Siemens SENTRON 5SL6616-6 miniature circuit breaker, 3P+N, B characteristic, 16A, 400V AC, 6kA breaking capacity per EN 60898 and IEC 60947-2, 4 MWU wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6616-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6616-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL6616-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL6616-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6616-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6616-6 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.8 W

Product details

The Siemens SENTRON 5SL6616-6 is a 4-pole (3P+N) miniature circuit breaker rated 16 A with a B tripping characteristic, designed for 400 V AC three-phase systems. It interrupts fault currents up to 6 kA per both EN 60898 and IEC 60947-2 — the standard household/commercial breaking capacity that matches most residential and light-infrastructure distribution boards.

B-curve trip — what it means on the line

The B characteristic trips between 3 and 5 times rated current (48–80 A magnetic trip), which makes it the right choice for resistive and general-purpose loads with low inrush — lighting circuits, socket outlets, control transformers. It avoids nuisance trips that a C-curve might tolerate but that a B-curve catches faster on short circuits.

The breaker occupies 4 modular width units (72 mm wide) on a standard DIN rail, with a depth of 76 mm and installation depth of 70 mm.

Environmental range and material compliance

Rated for ambient temperatures from -40 °C to 75 °C, halogen-free and silicon-free throughout, with pollution degree 2 and overvoltage category III. That makes it suitable for outdoor-rated enclosures in cold climates and for installations where outgassing from a fault must not corrode nearby contacts.

Frequently asked questions

What is the difference between 5SL6616-6 and 5SL4363-7?

The 5SL4363-7 is a 3-pole (3P) C-curve 63 A breaker with a 10 kA breaking capacity, while the 5SL6616-6 is a 3P+N B-curve 16 A breaker at 6 kA. The 5SL4363-7 is wider (54 mm vs 72 mm) and handles higher fault levels, but the 5SL6616-6 includes a switched neutral pole and is sized for lower-current, low-inrush circuits. They are not drop-in replacements without rewiring — the pole count and width differ.

Where can I buy the 5SL6616-6?

The 5SL6616-6 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
5SL6616-6