Siemens 5SL6616-7 SENTRON MCB, 400V 6kA 3P+N C-Curve 16A

MPN5SL6616-7
Active

Siemens SENTRON miniature circuit breaker, 5SL6616-7, 3P+N, 400 V AC, 6 kA, C-curve, 16 A, 4 MW units.

$19.05Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6616-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6616-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL6616-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL6616-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6616-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6616-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.6 W

Product details

The Siemens SENTRON 5SL6616-7 is a 4-pole (3P+N) miniature circuit breaker rated 16 A with a C-curve trip characteristic, designed for 400 V AC three-phase residential and infrastructure panels. Its 6 kA breaking capacity per EN 60898 (and matching 6 kA per IEC 60947-2) covers standard fault levels in most building distribution boards — enough for a lighting submain or a small pump circuit, but not for high-fault industrial switchgear where you'd look for 10 kA or higher.

The 5SL6616-7 occupies 4 modular width units (72 mm wide) on a standard DIN rail, with a depth of 76 mm and an installation depth of 70 mm behind the panel face. It mounts in any position, which simplifies layout in crowded enclosures. Sealable design (padlockable toggle) allows lockout/tagout on the breaker handle.

Frequently asked questions

What is the breaking capacity of 5SL6616-7?

6 kA per EN 60898 and 6 kA per IEC 60947-2 at 400 V AC.

How does 5SL6616-7 compare to 5SL4363-7?

5SL4363-7 is a 3-pole (not 3P+N) version with a 10 kA breaking capacity, one fewer modular width (3 MW vs 4 MW), and higher per-pole power loss (5 W vs 1.6 W). It drops into the same DIN-rail footprint but cannot switch the neutral — the 5SL6616-7 switches all three phases plus neutral, which is required for some regional wiring codes.

Where can I buy 5SL6616-7?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.