Siemens 5SL6616-7MB — 4-Pole MCB (DIN Rail)

Siemens 5SL6616-7MB SENTRON MCB, 3P+N, C-16A, 6kA

MPN5SL6616-7MB
Active

Siemens SENTRON 5SL6616-7MB miniature circuit breaker, 3P+N, C characteristic, 16 A rated, 6 kA breaking capacity at 400 V AC, 4 MW units wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6616-7MB — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6616-7MB — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL6616-7MB — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL6616-7MB — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6616-7MB — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6616-7MB — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.6 W

Product details

Ratings and derating

The 5SL6616-7MB: The C-curve (tripping characteristic class C) means the breaker trips at 5 to 10 times rated current — typical for mixed resistive and inductive loads like lighting and small motor circuits. At 30 °C ambient it carries the full 16 A; at 40 °C it derates to 15.2 A, and at 45 °C to 14.88 A. That derating matters if the breaker sits in a warm enclosure — plan the load accordingly. The 1.6 W power loss per pole at rated current in hot operating state adds up to 6.4 W total for the 4-pole unit, which should be factored into enclosure thermal calculations.

Mounting and integration

Snaps onto DIN rail in any mounting position. Occupies 4 modular width units (each 18 mm, so 72 mm total width). Installation depth is 70 mm; overall depth is 76 mm. The IP20 rating with connected conductors means it's protected against finger contact but not water ingress — standard for enclosed distribution boards. Sealable design allows locking the toggle position for anti-tamper requirements. Supplementary devices (auxiliary switches, shunt trips, under-voltage releases) can be installed on the side.

Environmental and compliance

Halogen-free and silicon-free construction — relevant for environments sensitive to corrosive off-gassing (data centers, clean rooms, marine). Operating temperature range from -40 °C to 75 °C covers extreme cold storage and hot panel conditions. Pollution degree 2 and overvoltage category III suit fixed installations in building distribution. The energy limitation class 3 means it limits let-through energy effectively for downstream equipment protection.

Sourcing and lifecycle

The lifecycle stage is current — no end-of-life notice, no last-time-buy window. This is a standard catalog item from the SENTRON family, so it's straightforward to specify into a BOM. Quoted to order against an RFQ; availability and current pricing confirmed at quote time.

Frequently asked questions

What is the breaking capacity of 5SL6616-7MB?

6 kA at 400 V AC per both EN 60898 and IEC 60947-2. That's the standard breaking capacity for this SENTRON series.

What is the difference between 5SL6616-7MB and 5SL4363-7?

The 5SL4363-7 is a different pole/current variant. The 5SL6616-7MB is a 3P+N 16 A C-curve; the 5SL4363-7 is a different configuration. They share the same DIN-rail footprint and SENTRON platform, but the pole count and rating differ — verify the specific variant for your BOM line.

Where can I buy 5SL6616-7MB?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.