Siemens 5SL6620-7 — 4-Pole MCB (DIN Rail)

Siemens 5SL6620-7 SENTRON MCB, 3P+N, C-curve, 20A, 6kA

MPN5SL6620-7
Active

Siemens SENTRON 5SL6620-7 miniature circuit breaker, 3P+N, 20 A, C tripping characteristic, 6 kA breaking capacity per EN 60898, 400 V AC, 4 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6620-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6620-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC20 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
5SL6620-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-26 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SL6620-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6620-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6620-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

What this MCB is and what the ratings mean for fit

The 5SL6620-7: The 4-pole, 4-module-width (72 mm) footprint snaps onto standard DIN rail and fits any mounting position. Depth is 76 mm, installation depth 70 mm — the extra 6 mm is the handle throw, so allow clearance in the enclosure door. Rated for overvoltage category III and pollution degree 2, which is the standard for fixed-installation distribution boards. IP20 with connected conductors means it's protected against finger contact but not against moisture — keep it inside a rated enclosure in wet locations.

Panel integration and compliance notes

Sealable design allows the installer to lock the handle in the OFF position with a padlock — useful for lockout/tagout on a final subcircuit without pulling the main disconnect. Halogen-free and silicon-free construction matters if the breaker lives in a clean room or a zone where outgassing during a fault could contaminate optics or electronics. Touch protection is built in; no separate finger-duct shield needed on the line side. Mechanical service life is 10 000 switching cycles typical — fine for branch-circuit protection where the breaker operates a few times a year, not for frequent switching duty (use a contactor for that).

Frequently asked questions

What is the closest functional second-source to the 5SL6620-7?

The 5SL3340-7CC is the closest sibling: same poles (4), same C curve, same 6 kA breaking capacity. The difference is 3P+N (switched neutral, no protection) vs 4P (all poles protected). Choose based on whether your neutral needs overcurrent protection.

What is the depth and width of the 5SL6620-7?

Depth is 76 mm, width is 72 mm, which corresponds to 4 modular width units. Installation depth is 70 mm.

Will the 5SL6620-7 drop into a panel specified around the 5SL3340-7CC without rewiring?

Yes, both are 4-pole, 4-module-width (72 mm) DIN-rail devices with the same 6 kA breaking capacity and C curve. The only wiring difference: the 5SL6620-7 switches the neutral but does not protect it, so if the original design used the neutral as a protected pole, you must verify the neutral conductor is sized for fault current — otherwise the swap is mechanical and electrical drop-in.

MPN
5SL6620-7