Siemens 5SL6625-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL6625-6 SENTRON MCB, 4P B-Curve 25 A 6 kA

MPN5SL6625-6
Active

Siemens SENTRON, miniature circuit breaker, 5SL6625-6, 4-pole (3P+N), B-curve, 25 A rated at AC 400 V, 6 kA breaking capacity per IEC 60898 and IEC 60947-2.

$15.24Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6625-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6625-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC25 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
5SL6625-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-26 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL6625-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6625-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)Periodically +55°C, max. 95% humidity

Product details

What this 4-pole B-curve MCB does

Rated 25 A at AC 400 V with a B-curve tripping characteristic, it protects against short-circuit and overload in residential and infrastructure circuits where the inrush current is low — lighting, socket outlets, control transformers.

The 5SL6625-6 occupies 4 modular-width units (72 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm — standard for a 4-pole SENTRON 5SL6. IP20 with connected conductors; the touch-protection feature means the terminals are shrouded when wired, meeting the finger-probe requirement for distribution boards. The neutral conductor is switched internally, so no separate neutral link is needed downstream.

Thermal derating and environmental range

At 40 °C it derates to 23.79 A; at 45 °C to 23 A; at 55 °C to 21.85 A. If the panel runs warm — say a crowded enclosure near a boiler or drive — factor that curve into the load calculation.

Frequently asked questions

What is the breaking capacity of 5SL6625-6?

6 kA per both EN 60898 and IEC 60947-2 — the standard fault-interrupt rating for domestic and light commercial distribution boards.

Does 5SL6625-6 switch the neutral?

Yes, it is a 4-pole (3P+N) MCB with internal neutral switching, so no separate neutral link is required downstream.

Where can I buy 5SL6625-6 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.