Skip to main content
Siemens 5SL6632-7 — 4-Pole MCB (DIN Rail)

Siemens 5SL6632-7 SENTRON MCB, 3P+N, 32 A, C Curve, 6 kA

MPN5SL6632-7
Active

Siemens SENTRON 5SL6632-7 miniature circuit breaker, 3P+N, 32 A, C tripping characteristic, 6 kA breaking capacity at 400 V AC, 4 MW units, IP20 with conductors.

$25.40Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL6632-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL6632-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SL6632-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL6632-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL6632-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL6632-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)3.1 W

Product details

The closest peer in the SENTRON family is the 5SL4363-7 — same depth (76 mm) and height (90 mm), same C curve, same 32 A rating. Two differences matter: the 5SL4363-7 is 3-pole (no switched neutral), so it occupies 3 MW units (54 mm) instead of 4. If your panel needs a switched neutral and the fault level stays under 6 kA, the 5SL6632-7 is the correct fit. If the fault level exceeds 6 kA or you don't need neutral switching, the 5SL4363-7 is the higher-rated alternative — but verify the neutral bar arrangement; a 3P breaker leaves the neutral solid.

Panel integration — DIN rail, sealable, halogen-free

Four modular width units (72 mm) — plan the rail space accordingly. Halogen-free and silicon-free materials reduce toxic smoke and silicone outgassing in enclosed panels — relevant for food processing or electronics assembly lines. Installation depth 70 mm — leaves clearance behind the DIN rail for wiring.

Frequently asked questions

What is the breaking capacity of 5SL6632-7?

6 kA per EN 60898 and IEC 60947-2 at 400 V AC. That is the rated short-circuit capacity for this MCB.

What is the difference between 5SL6632-7 and 5SL4363-7?

The 5SL6632-7 is 3P+N (4 MW units, 72 mm wide) with a 6 kA breaking capacity. The 5SL4363-7 is 3P (3 MW units, 54 mm wide) with a 10 kA breaking capacity. Both are 32 A, C curve, same depth and height. Choose based on whether you need a switched neutral and the fault level at the panel.

Where can I buy 5SL6632-7?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response.

MPN
5SL6632-7