Skip to main content
Siemens 5SL7104-7RC — 1-Pole MCB (DIN Rail)

Siemens 5SL7104-7RC Betagard MCB, 1P C-curve 4A 15kA

MPN5SL7104-7RC

Siemens Betagard 5SL7104-7RC miniature circuit breaker, 1-pole, C-curve, 4 A, 15 kA (EN 60898) / 20 kA (IEC 60947-2), 240/415 V AC, 1 MW unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL7104-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameBetagard
Number of poles1
Pole design1P
Application suitabilityIndustry
5SL7104-7RC — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL7104-7RC — Mounting & Connection
ParameterValue
Mounting positionany
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SL7104-7RC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens Betagard 5SL7104-7RC is a 1-pole miniature circuit breaker with a C-curve trip characteristic, rated 4 A at 240 V AC single-phase and 415 V AC multi-phase.

The 4 A rating governs the continuous thermal load; expect nuisance trips if the branch draws above 4 A sustained. That dual rating gives the buyer flexibility to spec this into either a commercial or industrial BOM without swapping part numbers. Rated for 240 V AC single-phase and 440 V AC multi-phase, it covers standard 230/400 V three-phase panels. The 50/60 Hz frequency range is universal for mains supplies worldwide.

Panel integration and environment

Mounting position is unrestricted. Sealable — the toggle can be locked in the off position with a padlock, meeting lockout/tagout requirements. Halogen-free and silicon-free construction reduces toxic gas and silicone outgassing in sensitive environments.

Frequently asked questions

What is the breaking capacity of 5SL7104-7RC?

15 kA per EN 60898 and 20 kA per IEC 60947-2. The higher rating applies when the MCB is used in industrial distribution per IEC 60947-2.

What is the difference between 5SL7104-7RC and the SENTRON 5SL6006-7?

The 5SL7104-7RC is a Betagard-branded 1-pole MCB with 15/20 kA breaking capacity, rated for industry. The 5SL6006-7 is a SENTRON-branded 1P+N unit with a 6 kA breaking capacity per EN 60898, rated for residential/infrastructure use. The 5SL7104-7RC has a higher fault-current rating and is designed for industrial panels; the 5SL6006-7 includes neutral switching and is intended for residential distribution boards. They are not drop-in replacements — the pole count and breaking capacity differ.

Where can I buy 5SL7104-7RC?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SL7104-7RC