Skip to main content
Siemens 5SL7202-7RC — 2-Pole MCB (DIN Rail)

Siemens Betagard 5SL7202-7RC MCB, 2-Pole C-Curve 15kA

MPN5SL7202-7RC

Siemens Betagard miniature circuit breaker, 5SL7202-7RC, 2-pole, C-curve, 415 V AC, 15 kA (EN 60898) / 20 kA (IEC 60947-2), 2 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL7202-7RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameBetagard
Application environmentIndustry
5SL7202-7RC — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value415 V
5SL7202-7RC — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SL7202-7RC — Mechanical
ParameterValue
Modular width units2
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL7202-7RC — Environmental
ParameterValue
Pollution degree2
5SL7202-7RC — Specifications
ParameterValue
According to EN 60898 rated value15 kA
With single-phase operation at AC rated value440 V

Product details

What the ratings mean for fit

The Siemens Betagard 5SL7202-7RC is a 2-pole miniature circuit breaker rated 415 V AC with a C-curve tripping characteristic. The 15 kA breaking capacity per EN 60898 covers most commercial and light industrial panelboard applications; the 20 kA rating per IEC 60947-2 gives headroom for higher-fault installations where the upstream transformer is close. The C-curve means the magnetic trip operates at 5 to 10 times rated current — standard for motor and lighting circuits where inrush is moderate. The 2-pole design switches both phase and neutral, and the 2-module-width (18 mm per pole) footprint fits standard DIN-rail enclosures. Rated for industrial environments with overvoltage category III and pollution degree 2, this MCB is suitable for fixed installations inside control panels. The IP20 rating applies with conductors connected — the breaker itself is not sealed against washdown, so it belongs inside a cabinet, not on the machine exterior.

Integration and compliance

Mounts in any position on a DIN rail. Depth is 76 mm, installation depth 70 mm — verify enclosure depth clearance if retrofitting into a shallow panel. The 18 mm width per pole (36 mm total for 2 poles) occupies two modular units. Sealable, halogen-free, and silicon-free construction suits environments where outgassing or contamination is a concern. Vibration resistant per IEC 60068-2-6, with a mechanical service life of 10 000 operating cycles typical. Power loss is 1.2 W per pole at rated current in hot operating state — negligible for thermal budgeting in a populated enclosure.

Frequently asked questions

Where can I buy 5SL7202-7RC and get a price?

We source this part to order against an RFQ. Submit a request for quote and we will confirm availability and current pricing.

What is the breaking capacity of 5SL7202-7RC?

15 kA per EN 60898 and 20 kA per IEC 60947-2 at 415 V AC. The higher IEC figure applies when the breaker is certified under that standard, giving additional fault-current headroom.

Will 5SL7202-7RC drop into a panel specified around 5SL4363-7?

No, not without rewiring. The 5SL7202-7RC is a 2-pole breaker (36 mm wide, 2 modular units), while the 5SL4363-7 is a 3-pole breaker (54 mm wide, 3 modular units). The panel's DIN-rail space and the number of conductors served are different.

MPN
5SL7202-7RC