Siemens 5SL7204-8RC — 2-Pole MCB (DIN Rail)

Siemens Betagard 5SL7204-8RC MCB, 2P D 4 A, 15 kA EN 60898

MPN5SL7204-8RC

Siemens Betagard 5SL7204-8RC miniature circuit breaker, 2-pole, D tripping characteristic, 4 A, 15 kA (EN 60898) / 20 kA (IEC 60947-2), 415 V AC, 2 MW, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL7204-8RC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameBetagard
Application environmentIndustry
5SL7204-8RC — Electrical
ParameterValue
Number of poles2
Supply voltage at AC rated value415 V
5SL7204-8RC — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SL7204-8RC — Mechanical
ParameterValue
Modular width units2
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SL7204-8RC — Environmental
ParameterValue
Pollution degree2
5SL7204-8RC — Specifications
ParameterValue
According to EN 60898 rated value15 kA
With single-phase operation at AC rated value440 V

Product details

D-curve 4 A MCB for industrial branch circuits

IP20 with connected conductors — touch-safe when wired, but not for wet or washdown zones. Sealable, halogen-free, silicon-free construction suits controlled-atmosphere or clean-room adjacent panels where outgassing matters.

Snap-on DIN rail mount, 2 MW wide. Vibration resistant per IEC 60068-2-6 — holds calibration on machine-mounted subpanels. Mechanical service life 10,000 operating cycles typical. Rated for 50/60 Hz supply.

How the 5SL7204-8RC differs from a standard C-curve 2-pole

The 5SL7204-8RC uses a D tripping characteristic (10-20× In magnetic trip), while the common 2-pole SENTRON sibling 5SY7206-7CC uses a C curve (5-10× In). For a 4 A circuit, the D-curve holds through the inrush of a small contactor coil or a 0.75 kW motor start that would trip a C-curve. The trade-off: reduced protection for low-level faults — D-curve is not for general-purpose socket outlets or lighting. The 5SL7204-8RC also carries a higher breaking capacity (15/20 kA vs 30 kA per IEC 60947-2 on the 5SY7206-7CC), so it's suited for lower-SCCR distribution boards rather than high-fault industrial mains.

Frequently asked questions

Will 5SL7204-8RC drop into a panel specified for 5SL6120-7?

Not as a direct swap without rewiring. The 5SL6120-7 is a 1-pole C-curve unit; the 5SL7204-8RC is 2-pole D-curve. Same depth (76 mm) and height (90 mm), but width doubles from 1 MW to 2 MW. The D-curve also changes coordination — verify selectivity with downstream devices.

MPN
5SL7204-8RC