Siemens 5SL7316-3RC — Miniature Circuit Breakers (MCB)

Siemens 5SL7316-3RC Betagard MCB, 16A 3P K-Char 15kA

MPN5SL7316-3RC

Siemens Betagard miniature circuit breaker, 5SL7316-3RC, 16 A, 3-pole, K characteristic, 15 kA breaking capacity per IEC/EN 60898 & 60947-2, 415 V AC, 3 MW units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SL7316-3RC — Ratings
ParameterValue
Overvoltage categoryIII
5SL7316-3RC — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

16 A, K characteristic, 3-pole — Betagard MCB for industrial loads

The Siemens 5SL7316-3RC is a 3-pole miniature circuit breaker from the Betagard line, rated 16 A with a K tripping characteristic and a 15 kA breaking capacity under both IEC/EN 60898 and IEC 60947-2.

The Betagard series is Siemens' economy MCB line for industrial and commercial applications where full SENTRON functionality is not required. It shares the same 76 mm depth and 90 mm height as the SENTRON 5SL4 and 5SY4 series, so it fits the same DIN-rail enclosures and busbar systems.

Halogen-free and silicon-free construction, with a sealable design for tamper-proof locking.

Delta: Betagard vs SENTRON 5SL4363-7

The closest functional peer within the Siemens MCB family is the SENTRON 5SL4363-7 — same 3-pole, 16 A, same 76×54×90 mm footprint, same 15 kA breaking capacity. The deciding difference is the tripping characteristic: the Betagard 5SL7316-3RC uses a K curve (for motor/inductive loads), while the 5SL4363-7 uses a C curve (for general-purpose resistive/light inductive loads). If your panel was specified around a C-curve breaker and you swap in a K-curve, you may lose coordination on downstream branch circuits with low inrush — verify the load type before substituting.

Frequently asked questions

What is the breaking capacity of 5SL7316-3RC?

15 kA per both IEC/EN 60898 and IEC 60947-2 at the rated voltage.

What is the K characteristic used for?

The K curve tolerates higher inrush currents than a C curve, making it suitable for motor starters, transformers, and solenoid loads where brief startup surges would trip a standard breaker.

Where can I buy 5SL7316-3RC?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SL7316-3RC drop into a panel specified for 5SL4363-7?

Physically yes — same 76×54×90 mm footprint, same DIN-rail mounting, same 3 MW units. The functional difference is the tripping curve: K vs C. Verify load inrush characteristics before substituting.