Siemens 5SL7425-3RC — 4-Pole MCB (DIN Rail)

Siemens 5SL7425-3RC Betagard MCB, 4P K-curve 25 A, 15 kA

MPN5SL7425-3RC

Siemens Betagard 5SL7425-3RC miniature circuit breaker, 4-pole, K tripping characteristic, 25 A rated at 415 V AC, 15 kA breaking capacity per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SL7425-3RC — Identification
ParameterValue
Brand nameBetagard
5SL7425-3RC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC25 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
5SL7425-3RC — Protection
ParameterValue
Tripping characteristic (trip curve)K
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SL7425-3RC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL7425-3RC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

What this K-curve 4-pole MCB does on the line

The Siemens Betagard 5SL7425-3RC is a 4-pole miniature circuit breaker with a K tripping characteristic, rated 25 A at 415 V AC and 15 kA breaking capacity per both EN 60898 and IEC 60947-2. It holds 28 A at 30 °C and derates to 23.4 A at 60 °C, so if the panel's running hot, factor that in when sizing the branch circuit.

Panel fit and mounting details

The housing is IP20 with conductors connected, which is standard for a distribution board interior; it's not a washdown part.

Rated for -40 °C to 75 °C ambient, so it handles unheated enclosures in cold climates or hot summer days. Halogen-free and silicon-free construction, which matters if the panel serves sensitive electronics or needs low-smoke, zero-halogen cabling zones. Overvoltage category III, so it's suitable for fixed-installation distribution boards, not just downstream equipment. Touch protection is built into the terminals.

The 15 kA breaking capacity at 415 V AC (per IEC 60947-2) and also 15 kA per EN 60898 gives solid SCCR headroom for most commercial and light industrial distribution boards. It's a 4-pole design with no neutral conductor switching — the neutral pole is switched, but the product component note says neutral conductor switching is not present, meaning it's a solid neutral or switched-neutral variant that doesn't break the neutral under fault.

Frequently asked questions

How do I get current pricing and availability for 5SL7425-3RC?

Send an RFQ — we source this part to order through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings for 5SL7425-3RC?

4-pole, K-curve, 25 A rated at 415 V AC, 15 kA breaking capacity per IEC 60947-2 and EN 60898. It derates from 28 A at 30 °C to 23.4 A at 60 °C.

What compliance documentation does this brand provide for 5SL7425-3RC?

It carries ratings per IEC 60947-2 and EN 60898, and is classified as halogen-free and silicon-free. For specific documentation like RoHS or UL, the manufacturer's declaration should be requested at order time.

MPN
5SL7425-3RC