Siemens 5SM1111-0 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM1111-0 RCCB, 16A, 10mA, 2-Pole, 230V AC

MPN5SM1111-0

Siemens SENTRON series, RCCB, 5SM1111-0, 2-pole, 16 A rated at 40 °C, 10 mA residual trip, 230 V AC, 10 kA SCCR, DIN rail mount.

$328.78Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM1111-0 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM1111-0 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM1111-0 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-5 °C
Installation depth55 mm
5SM1111-0 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SM1111-0 — Electrical
ParameterValue
Operational current / at AC / rated value16 A

Product details

The Siemens SENTRON 5SM1111-0 is a 2-pole residual current circuit breaker (RCCB) rated for 16 A at 40 °C with a 10 mA residual trip threshold, designed for 230 V AC single-phase circuits. It provides earth leakage protection per IEC 61008-1, tripping instantaneously on AC-type residual currents above 10 mA — the threshold that covers personnel protection against direct contact in wet or conductive environments.

The 10 mA trip rating is the critical selection parameter: it is the lowest standard sensitivity for RCCBs, used where the installation requires enhanced protection against ventricular fibrillation — typically in medical locations, wet rooms, or circuits supplying hand-held equipment. The 16 A continuous rating holds through 45 °C ambient, then derates linearly to 11.2 A at 70 °C, so the thermal limit in a warm panel is the real ampacity, not the 16 A nameplate. The short-circuit current rating (SCCR) is 10 kA per IEC 61008-1, but note the conditional rating against EN 60898 is only 0.5 kA — the lower figure applies when the RCCB is used as a stand-alone device without an upstream MCB or fuse to limit the let-through energy. For the 10 kA rating to hold, the RCCB must be backed by a suitable overcurrent protective device with a let-through I²t of 70 000 A²·s or less. The 10 000 mechanical switching cycles are typical for an RCCB in a distribution board — the part is designed for infrequent manual operation (test button and isolation), not for switching loads on every cycle. The IP20 rating is standard for enclosed distribution boards; the protection applies only with conductors connected and the board closed.

The 55 mm installation depth fits flush in most domestic and light-commercial distribution boards. The silicon-free construction makes it suitable for use in potting or encapsulation environments where silicone outgassing could contaminate contacts or optical components.

Frequently asked questions

What is the 5SM1111-0 used for?

It is a 2-pole residual current circuit breaker (RCCB) that protects a 230 V AC single-phase circuit against earth leakage faults, tripping at 10 mA residual current. Typical applications include personnel protection in wet areas, medical locations, and circuits supplying hand-held equipment where enhanced sensitivity is required.

Where can I buy the 5SM1111-0?

The 5SM1111-0 is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at the time of quotation — submit an RFQ for a firm price and delivery commitment.

Will the 5SM1111-0 drop into a panel built for the 5SY7140-8CC?

Both are 2-pole, DIN-rail-mounted RCCBs from the Siemens SENTRON family, sharing the same 2-module-width footprint and 55 mm depth. The critical difference is the trip threshold: the 5SM1111-0 trips at 10 mA, while the 5SY7140-8CC is a higher-sensitivity variant. If the panel wiring and upstream protection are sized for a 10 mA device, the 5SM1111-0 will physically and electrically fit without rewiring.