Skip to main content
Siemens 5SM1312-6 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM1312-6 RCCB, 25 A, 30 mA, 2-Pole, Type A,

MPN5SM1312-6

Siemens SENTRON RCCB, 5SM1312-6, 2-pole, Type A, 25 A, 30 mA, 230 V AC, 50 Hz, DIN rail mount, current lifecycle.

$132.02Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM1312-6 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM1312-6 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM1312-6 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Installation depth55 mm
5SM1312-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SM1312-6 — Electrical
ParameterValue
Operational current / at AC / rated value25 A

Product details

The Siemens SENTRON 5SM1312-6 is a 2-pole residual current circuit breaker (RCCB) with a 25 A operational current rating and a 30 mA trip threshold, designed for 230 V AC, 50 Hz systems.

Key ratings and their meaning

The 25 A operational current matches common submain and feeder circuits; derating applies above 40 °C: at 50 °C it carries 24 A, at 60 °C 22 A, at 70 °C 20 A (–). The short-circuit current rating is 10 kA per the device's own rating, with a lower 0.5 kA limit when coordinated per EN 60898 or IEC 61008-1 — so on a high-fault panel, verify the upstream breaker's let-through stays within that coordination limit.

Snaps onto DIN rail (REG profile), occupies 2 modular width units — standard 18 mm per unit. Installation depth is 55 mm. Silicon-free construction matters for potting or coating processes where silicone contamination can cause adhesion failure.

Frequently asked questions

What is the 5SM1312-6 used for?

It is a 2-pole residual current circuit breaker (RCCB) used for personnel and equipment protection against ground faults in 230 V AC, 50 Hz circuits, typically in distribution boards.

What are the key ratings of the 5SM1312-6?

25 A operational current, 30 mA residual trip, Type A, 2-pole, 230 V AC, 50 Hz, 10 kA SCCR, and a mechanical service life of 10 000 switching cycles.

How do I get pricing and availability for the 5SM1312-6?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
5SM1312-6