Skip to main content
Siemens 5SM1316-6 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM1316-6 SENTRON RCCB, 63A 30mA Type A, 2-Pole

MPN5SM1316-6

Siemens SENTRON 5SM1 series, Residual Current Circuit Breaker (RCCB), 2-pole, Type A, 63 A rated, 30 mA trip, 230 V AC, instantaneous, DIN rail mount.

$222.78Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM1316-6 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM1316-6 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM1316-6 — Mechanical
ParameterValue
Mounting positionany
Maximum25 mm²
Minimum1.5 mm²
Installation depth55 mm
5SM1316-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM1316-6 is a SENTRON 5SM1-series 2-pole RCCB rated 63 A with a 30 mA Type A residual-current trip, 230 V AC, instantaneous response. This is the core spec that determines fit for a final-sub circuit — the 63 A frame handles the load side, the 30 mA sensitivity catches both sinusoidal and pulsating DC fault currents (Type A), which covers most modern electronics and variable-speed drives downstream. Mounts on DIN rail (REG), occupies 2 width units, installs in any position, and needs 55 mm of enclosure depth. The IP20 rating applies once the distribution board is closed with conductors connected.

Thermal derating and conductor sizing

Above that, the curve steps down: 60.48 A at 50 °C, 57.96 A at 55 °C, 55.44 A at 60 °C, 52.92 A at 65 °C, and 50.4 A at 70 °C. Terminals accept 1.5 mm² minimum to 25 mm² maximum conductor. That 25 mm² top end matches the 63 A rating comfortably.

Integration notes

Supply can land top or bottom — no mandatory orientation. The instantaneous design (no short-time delay) means it trips on the first half-cycle of a residual fault, which is the standard for personnel protection (30 mA). The 1 kA surge-current withstand rating covers inrush from downstream capacitive loads or surge arrestors without nuisance tripping. Mechanical endurance is 10,000 switching cycles typical. Silicon-free construction matters for automotive or electronics manufacturing environments where silicone outgassing can contaminate sensitive surfaces or bonding processes. Finger-and-back-of-hand shock protection means the terminals are shrouded against accidental contact during commissioning.

Frequently asked questions

Will 5SM1316-6 drop into a panel specified around 5SQ2570-2YA50?

Both are 2-pole, DIN-rail mount, 55 mm depth, 2 width units — same mechanical footprint. But the 5SQ2570-2YA50 is an MCB with no residual-current function; the 5SM1316-6 is an RCCB. The wiring and protection scheme are different. Physically fits; functionally replaces only if the circuit needs RCD protection.

MPN
5SM1316-6