Siemens 5SM1744-6 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM1744-6 SENTRON RCCB, 4P, 40A, 500mA, Type A, 10kA

MPN5SM1744-6

Siemens SENTRON 5SM1 series RCCB, 4-pole, type A, In 40 A, IΔn 500 mA, Un AC 400 V, 10 kA SCCR, instantaneous, DIN rail mount.

$415.80Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM1744-6 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM1744-6 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM1744-6 — Mechanical
ParameterValue
Mounting positionany
Maximum25 mm²
Minimum1.5 mm²
Installation depth55 mm
5SM1744-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM1744-6 is a 4-pole residual current operated circuit breaker (RCCB), type A, rated 40 A at 400 V AC with a 500 mA tripping residual current. It's an instantaneous design — no intentional delay — so it clears earth faults as fast as the fault current drives it past the 500 mA threshold. That makes it a fit for general-purpose protection where you need fast disconnection on a 4-wire (3-phase + neutral) circuit.

The 40 A rating holds across the 40 °C to 45 °C band without derating — still 40 A at both temperatures. Above that it steps down: 38.4 A at 50 °C, 36.8 A at 55 °C, 35.2 A at 60 °C, 33.6 A at 65 °C, and 32 A at 70 °C. If your enclosure runs hot, that's the curve you size against, not the nameplate 40 A. That's the standard choice for mixed-load panels where you can't guarantee a clean sine-wave fault.

DIN-rail fit and panel integration

Snaps onto a DIN rail (REG profile), occupies 4 width units, and the installation depth is 55 mm. Conductor range is 1.5 mm² minimum to 25 mm² maximum. IP20 rating applies with the distribution board closed and conductors connected — standard for enclosed panel gear. Finger and back-of-hand safe touch protection is built in, so an opened enclosure still offers basic shock protection as long as the conductors are terminated.

Frequently asked questions

What is the maximum and minimum conductor size for 5SM1744-6?

The terminals accept 1.5 mm² minimum up to 25 mm² maximum conductor cross-section.

Will 5SM1744-6 drop into a panel specified for 5SQ2670-2YA63?

Both are 4-pole SENTRON devices on a DIN-rail footprint with 55 mm installation depth and 4 width units, so the mechanical fit is the same. But 5SQ2670-2YA63 is a 63 A MCB (type C characteristic), not an RCCB — the function is different. You would need to re-engineer the protection scheme, not just swap the part.

MPN