Skip to main content
Siemens 5SM2622-0 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM2622-0 SENTRON RCD Unit, 2-Pole, 40 A, 300 mA, 23

MPN5SM2622-0
Active

Siemens SENTRON 5SM2622-0 RCD unit, 2-pole, type AC, In 40 A, IΔn 300 mA, Un AC 230 V, 2 modular width units, IP20.

$19.05Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SM2622-0 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM2622-0 — Identification
ParameterValue
Product designationRCD-unit
Product design / constructioninstantaneous
5SM2622-0 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-5 °C
Width71 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SM2622-0 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM2622-0 is a 2-pole residual current device (RCD) from the SENTRON series, rated 40 A with a 300 mA trip threshold for 230 V AC circuits. It is designed as an add-on RCD unit for the 5SY miniature circuit breaker line, fitting into the same DIN-rail mounting scheme at 2 modular width units (36 mm). Type AC detection means it responds to sinusoidal AC residual currents — the standard choice for general-purpose socket-outlet and lighting circuits where no rectified or pulsed DC fault currents are expected. The 300 mA rating is typical for fire-protection or submain protection, not for personal shock protection (which requires ≤30 mA).

Lifecycle and Sourcing

The 5SM2622-0 carries an Active lifecycle status, so it remains in Siemens' current production portfolio. No end-of-life notification or last-time-buy window is in effect. For volume or scheduled BOM requirements, the part is quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time.

Panel Integration and Environment

Mounts on standard DIN rail (fastening method REG) in any orientation, with a 70 mm installation depth that matches the 5SY MCB footprint. The 2-MW width (36 mm) occupies two adjacent 18 mm slots. Rated for overvoltage category III and pollution degree 2, so it is suited for distribution boards and sub-distribution panels in residential or commercial infrastructure. IP20 with connected conductors — enclosed panel required; not for washdown or outdoor exposure. Operating temperature range is -5 °C to 45 °C, with storage from -40 °C to 75 °C. The mechanical service life is rated at 10,000 operating cycles typical. Power dissipation per pole at rated current in hot state is 1.9 W — factor into enclosure thermal calculations when grouping multiple units.

Frequently asked questions

Where can I buy 5SM2622-0?

The 5SM2622-0 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between 5SM2622-0 and 5SL4363-7?

The 5SM2622-0 is a 2-pole RCD unit (type AC, 40 A, 300 mA) designed as an add-on for 5SY MCBs. The 5SL4363-7 is a standalone 3-pole miniature circuit breaker (C-curve, 63 A, 400 V) — a different device class. They share the SENTRON brand and DIN-rail mounting but are not functionally interchangeable; the 5SM2622-0 provides residual current protection while the 5SL4363-7 provides overcurrent protection only.

What compliance documentation is available for 5SM2622-0?

As a Siemens SENTRON product, the 5SM2622-0 is designed to meet applicable IEC/EN standards (IEC 61008 for RCCBs). RoHS and REACH compliance declarations are typically available from Siemens documentation portals. The part carries an overvoltage category III rating and pollution degree 2 per IEC 60947.

MPN
5SM2622-0