Specifications

5SM3111-6 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3111-6 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3111-6 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SM3111-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SM3111-6 — Electrical
ParameterValue
Operational current / at AC / rated value16 A

Product details

The Siemens 5SM3111-6 is a SENTRON residual current circuit breaker (RCCB) — 2-pole, 10 mA tripping threshold, Type A waveform detection, rated 16 A at 40 °C on a 230 V AC 50 Hz supply. Instantaneous trip, no intentional delay, so it clears ground faults on the first half-cycle. That 10 mA sensitivity catches leakage through electronics, variable-speed drives, and rectifier stages that a Type AC device would miss — common on modern mixed-load panels.

DIN-rail fit and thermal derating

Mounts on DIN rail (REG), 2 modular width units wide, 36 mm per unit. Depth is 70 mm — matches standard SENTRON RCCB profile, so it sits flush in a Siemens distribution board without protruding past the gland plate. Any mounting position allowed; supply line can enter top or bottom. IP20 with the distribution board installed and conductors connected — fine for enclosed panels, not for wet environments. Above that, derate linearly: 15.04 A at 50 °C, 14.08 A at 55 °C, 13.12 A at 60 °C, 12.16 A at 65 °C, 11.2 A at 70 °C. If the panel ambient hits 60 °C, the effective rating drops to 13.12 A — plan the load accordingly. Storage range is wider: -40 °C to 75 °C.

Breaking capacity and fault let-through

Surge current resistance 1 kA; permissible I²t is 70,000 A²·s. That let-through figure (7,500 kA — likely a data-entry unit mismatch for the rated conditional value) governs what the downstream wiring and devices see during a fault. Overvoltage category III, so it's rated for fixed-installation distribution panels, not plug-in portable gear.

Frequently asked questions

What is the residual current rating and type for 5SM3111-6?

10 mA tripping threshold, Type A waveform detection — catches pulsating DC residual currents from rectifiers and VFDs, not just sinusoidal AC leakage.

Does 5SM3111-6 have a short-time delay?

No — it is an instantaneous-trip RCCB (no short-term delayed switching function). Clears ground faults on the first half-cycle without intentional delay.