Siemens 5SM3111-6KL — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3111-6KL SENTRON RCCB, 16 A, 10 mA, Type A

MPN5SM3111-6KL

Siemens SENTRON 5SM3111-6KL, RCCB, 2-pole, Type A, In: 16 A, 10 mA, Un AC: 230 V, N left, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3111-6KL — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3111-6KL — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3111-6KL — Mechanical
ParameterValue
Mounting positionany
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SM3111-6KL — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM3111-6KL is a SENTRON residual current operated circuit breaker (RCCB), 2-pole, Type A, rated 16 A at 230 V AC, 50 Hz, with a 10 mA tripping residual current. The N-left variant means the neutral connection is on the left side of the device — a detail that matters when swapping into an existing panel layout without re-dressing the wiring.

The 10 mA trip threshold (Type A) catches pulsating DC fault currents on top of sinusoidal AC — common in modern loads with rectifiers, switching power supplies, or variable-speed drives. That's a tighter threshold than the standard 30 mA RCCB, so it's specified where personnel protection against ventricular fibrillation is the priority (e.g., wet locations, medical rooms, or portable equipment in industrial settings). The 16 A rated current matches the load side of a 16 A MCB in a sub-distribution board; you'd pair it downstream of a 16 A or 20 A miniature circuit breaker for coordinated overcurrent and earth-fault protection. Instantaneous design (no short-time delay) means it trips within a cycle on a residual fault — no intentional delay for selective coordination with downstream RCDs. That's the right choice for final circuits where speed matters more than discrimination.

IP20 with connected conductors — fine for indoor panel use, not for wet washdown zones.

Frequently asked questions

What is the 5SM3111-6KL used for?

It is a residual current operated circuit breaker (RCCB) that protects against earth faults in AC circuits up to 230 V, 16 A, with a 10 mA trip threshold for personnel protection.

Where can I buy the 5SM3111-6KL?

This part is sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time.

Will the 5SM3111-6KL drop into a panel specified around the 5SL6563-7BB?

The 5SM3111-6KL is an RCCB, while the 5SL6563-7BB is a miniature circuit breaker (MCB) — they serve different protection functions and are not direct drop-in replacements. However, both share the same 36 mm width, 90 mm height, and DIN-rail mounting, so they fit the same panel footprint if the wiring and protection scheme are re-engineered.