Siemens 5SM3314-6LA01 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3314-6LA01 SENTRON RCCB, 40 A, 30 mA, Type A, Sho

MPN5SM3314-6LA01

Siemens SENTRON 5SM3 series RCCB, 2-pole Type A short-time delayed, In: 40 A, IΔn: 30 mA, Un AC: 230 V, 10 kA SCCR, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SM3314-6LA01 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3314-6LA01 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SM3314-6LA01 — Mechanical
ParameterValue
Mounting positionany
Installation depth70 mm
5SM3314-6LA01 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM3314-6LA01 is a 2-pole SENTRON residual current circuit breaker (RCCB), Type A, short-time delayed, rated 40 A at 230 V AC with a 30 mA tripping threshold. It includes thermal overload protection, so it combines earth-fault and overcurrent protection in one DIN-rail module — a space-saving choice for final distribution circuits in residential, commercial, and light industrial panels where you need both ground-fault and overload coverage without a separate MCB. The short-time delayed design means it withstands transient surge currents up to 3 kA without nuisance tripping, making it suitable for circuits with capacitive inrush or switching transients.

Rated at 40 A continuous, it handles typical 230 V single-phase submain or feeder circuits up to about 9.2 kW resistive load. Overvoltage category III confirms it is rated for fixed-installation downstream of the utility meter. Conductor range accepts 1 to 16 mm² solid or stranded, covering 1.5 mm² lighting circuits up to 16 mm² feeder tails. Tightening torque of 2.5 to 3 N·m on the screw terminals — standard for this class; a torque screwdriver is recommended during panel build to avoid terminal overheating. Ambient temperature range of -25 to +45 °C and storage range of -40 to +75 °C cover most indoor panel environments. The IP20 rating is typical for DIN-rail devices inside an enclosed distribution board — it is not rated for wet or dusty locations without an outer enclosure.

Mounts on DIN rail in any orientation. The test button requires a minimum of 195 V to verify the electronics.

Frequently asked questions

What is 5SM3314-6LA01's conductor range?

Solid and stranded conductors from 1 to 16 mm². Terminal torque spec is 2.5 to 3 N·m.

What does Type A and short-time delayed mean on this RCCB?

Type A detects both sinusoidal AC and pulsating DC fault currents — needed on circuits with electronics or VFDs. Short-time delayed means it can ride through 3 kA surge currents without tripping, preventing nuisance trips on circuits with capacitive inrush.

Where can I buy 5SM3314-6LA01 and what is the lead time?

This part is available to order through our independent distribution channel. We quote and procure against an RFQ; current pricing and lead time are confirmed at quote time.

MPN
5SM3314-6LA01