Siemens 5SM3317-6 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM3317-6 RCCB, 80 A 30 mA Type A, 2-pole

MPN5SM3317-6

Siemens SENTRON 5SM3 series, 5SM3317-6, 2-pole RCCB, 80 A / 30 mA Type A, instantaneous, DIN-rail mount.

$232.83Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SM3317-6 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3317-6 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3317-6 — Mechanical
ParameterValue
Mounting positionany
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SM3317-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The 5SM3317-6 is a 2-pole residual-current circuit breaker (RCCB) from the Siemens SENTRON 5SM3 series, rated 80 A at 230 V AC with a 30 mA Type A tripping characteristic. The instantaneous design (no short-time delay) means it trips within the normal RCCB response window; use it where selectivity against a downstream delayed RCD is not required. Mounts on DIN rail (REG profile) in any orientation — top or bottom feed. At 36 mm wide (2.5 modular width units), it occupies two adjacent slots in a standard distribution board. IP20 only when the enclosure is closed and conductors are connected; not rated for wet or dusty environments without a higher-rated outer enclosure. Temperature derating is published from 40 °C to 70 °C in 5 °C steps: 80 A continuous up to 45 °C, then linearly down to 64 A at 70 °C.

Integration and compliance notes

Finger and back-of-hand safe per the protection-against-electrical-shock rating. Overvoltage category III — suitable for fixed-installation downstream of the service entrance. Silicon-free construction, which matters for applications where silicone outgassing can contaminate contacts or optics (e.g., adjacent to sensitive electronics in a sealed panel). Function letter F per DIN EN 61346-2 and DIN EN 81346-2 — protective-equipment function in the plant-modelling standard. The I²t value is 70 000 A²s; surge-current withstand is 1 kA. Test circuit minimum voltage is 100 V AC.

MPN
5SM3317-6