Skip to main content
Siemens 5SM3344-0LA — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3344-0LA SENTRON RCCB, 4-pole, 40 A, 30 mA, 400 V

MPN5SM3344-0LA

Siemens SENTRON 5SM3 series, 4-pole RCCB type AC, 40 A rated current, 30 mA trip sensitivity, 400 V AC, DIN rail mount, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SM3344-0LA — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3344-0LA — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SM3344-0LA — Mechanical
ParameterValue
Mounting positionany
Installation depth70 mm
5SM3344-0LA — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM3344-0LA is a SENTRON 4-pole residual current operated circuit breaker (RCCB), type AC, rated 40 A with a 30 mA trip threshold at 400 V AC. It includes thermal overload protection and is designed for instantaneous tripping on AC fault currents.

The 30 mA residual current trip is the standard for personnel protection in most IEC-based installations — it catches leakage through a human body to ground. The 10 kA SCCR at 400 V matches typical domestic and commercial fault levels; verify coordination with the upstream MCB or fuse.

Mounts on DIN rail (REG profile) in any position — no orientation restriction. The screw terminals accept solid or stranded conductors from 1.5 to 25 mm²; tighten to 2.5–3 N·m.

Finger and back-of-hand safe touch protection. Silicon-free construction. Ambient storage range -40 to +75 °C; operating range -5 to +45 °C. Mechanical service life 10 000 switching cycles typical.

Frequently asked questions

Where can I buy 5SM3344-0LA?

This part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer.

What conductor sizes does 5SM3344-0LA accept?

The screw terminals accept solid or stranded conductors from 1.5 mm² up to 25 mm².

Will 5SM3344-0LA fit a panel designed for 3VA2116-5HM42-0CC0?

No — the 3VA2116-5HM42-0CC0 is a moulded-case circuit breaker with a different footprint (86 mm depth, 140 mm width) and front terminals; the 5SM3344-0LA is a DIN-rail RCCB occupying 4 width units at 70 mm depth. They are not mechanically interchangeable without panel rework.

MPN
5SM3344-0LA