Siemens 5SM3344-6LB01 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM3344-6LB01 SENTRON RCCB, 4P, 40A, 30mA, Type A

MPN5SM3344-6LB01

Siemens SENTRON 5SM3 series RCCB, 4-pole, type A, short-time delayed, rated 40 A, 30 mA residual, 400 V AC, 10 kA SCCR, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SM3344-6LB01 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM3344-6LB01 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SM3344-6LB01 — Mechanical
ParameterValue
Mounting positionany
Installation depth70 mm
5SM3344-6LB01 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM3344-6LB01 is a SENTRON residual current operated circuit breaker (RCCB) — 4-pole, type A, short-time delayed, rated 40 A at 400 V AC with a 30 mA trip threshold. Type A means it detects pulsating DC residual currents on top of sinusoidal AC, so it covers rectifier-fed loads like VFDs, switching power supplies, and modern lighting ballasts that a plain AC-type RCCB would miss. The 30 mA trip provides personal protection against direct contact; the 40 A continuous rating matches a typical submain or feeder feeding a mixed load panel. Short-time delayed (selective) design means it withstands brief inrush without tripping, coordinating with downstream MCBs so only the faulted branch opens — not the whole panel. Rated short-circuit withstand is 10 kA, surge current resistance 3 kA, so it holds under fault conditions that would weld contacts on a standard RCCB.

Panel integration

Snaps onto DIN rail (REG mounting), occupies 4 width units (about 72 mm at 18 mm/module). Mounting position any; supply feed top or bottom, no orientation restriction. Terminal torque spec is 2.5 to 3 N·m, accepting solid or stranded copper from 1.5 up to 25 mm² — enough for the 40 A feed without pigtailing down. Finger and back-of-hand safe terminals reduce arc-flash exposure during live troubleshooting.

Frequently asked questions

What does type A and short-time delayed mean for this RCCB?

Type A detects both AC sinusoidal and pulsating DC residual currents, covering loads with rectifiers (VFDs, SMPS, LED drivers). Short-time delayed (selective) means it tolerates brief inrush without nuisance tripping, coordinating with downstream MCBs so only the faulted branch opens.

What wire sizes does the 5SM3344-6LB01 accept?

Solid and stranded copper from 1.5 mm² up to 25 mm², terminated under screw terminals torqued to 2.5–3 N·m.

Where can I buy the 5SM3344-6LB01?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no stock count or price published here.

MPN
5SM3344-6LB01